MétaCan
Menu
Back to cohort
Record W2917435051 · doi:10.1002/mp.13454

Robust cerebrovascular blood velocity and flow rate estimation from 4D‐<scp>CTA</scp>

2019· article· en· W2917435051 on OpenAlexafffund
Pierre Bouillot, Olivier Brina, Christophe Chnafa, Nicole M Cancelliere, María Isabel Vargas, Ivan Radovanovic, Timo Krings, David A. Steinman, Vítor Mendes Pereira

Bibliographic record

VenueMedical Physics · 2019
Typearticle
Languageen
FieldMedicine
TopicCerebrovascular and Carotid Artery Diseases
Canadian institutionsUniversity of TorontoToronto Western HospitalUniversity Health Network
FundersSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungHeart and Stroke Foundation of Canada
KeywordsPulsatile flowBlood flowBiomedical engineeringDisplacement (psychology)Computed tomography angiographyFlow (mathematics)AngiographyFlow velocityImage resolutionVolumetric flow rateNuclear medicineMedicineComputer scienceRadiologyMathematicsArtificial intelligencePhysicsCardiologyGeometry

Abstract

fetched live from OpenAlex

PURPOSE: Blood velocity and flow rate information may be helpful for a wide variety of applications, but it often requires separate acquisitions. The dynamic information combined with the high spatial resolution of four-dimensional computed tomography angiography (4D-CTA) offers the possibility to quantify blood flow simultaneous to vascular anatomy. METHODS: A 4D-CTA clinical protocol with a novel dedicated postprocessing were validated in vitro in a patient-specific model, and tested in a pilot study of six patients. Blood flow was assessed in both internal carotid (ICAs) and vertebral (VAs) arteries by analyzing spatial displacement of contrast agent in the form of time-intensity curves (TICs). Unlike previous approaches, it does not require any a priori assumptions about TIC shape, but rather computes mean velocity and flow rates from the spatial displacement of the TICs along the automatically segmented vessels. RESULTS: In vitro experiments showed good agreement between 4D-CTA and flowmeter measurements under steady and pulsatile flow conditions. In vivo measurements exhibited large interpatient variability of the TIC shapes, from which blood flow rates could nevertheless be successfully measured in all patients and investigated vessels. On average, measured flow rates were 3.2 ± 0.7 ml/s (in ICAs) and 1.3 ± 0.8 ml/s (in VAs) consistent with previous reference standards. Contrary to our novel approach, which considered the full TIC shape, application of previous time-to-peak analyses based on idealized TIC shapes showed limited reliability. CONCLUSIONS: We demonstrate the high potential of 4D-CTA for assessing blood velocity and flow rate in addition to anatomical evaluation. The wide variety of TIC shapes encountered in vivo highlights the importance of an adaptive TIC analysis as proposed in the present work.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.003
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.001
Science and technology studies0.0000.000
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.213
Teacher spread0.203 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations14
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicCerebrovascular and Carotid Artery DiseasesFrench-language works237,207