MétaCan
Menu
Back to cohort

Effect of Trendelenburg position and lower-body positive pressure on neck fluid distribution

2019· article· en· W2917566197 on OpenAlexafffund
Azadeh Yadollahi, Bhajan Singh, Philip J. Millar, Daniel Vena, John S. Floras, T. Douglas Bradley

Bibliographic record

VenueJournal of Applied Physiology · 2019
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsUniversity of GuelphToronto Rehabilitation InstituteUniversity of TorontoUniversity Health Network
FundersCanadian Institutes of Health Research
KeywordsSupine positionTrendelenburg positionMedicineTrendelenburgAnesthesiaHemodynamicsCardiology

Abstract

fetched live from OpenAlex

Fluid that shifts out of the legs and into the neck when supine can contribute to upper-airway narrowing. The present study investigates the relative contributions of vascular and extravascular fluid to the total accumulation of neck fluid volume (NFV). In 22 healthy awake participants (8 women), aged 42 ± 9 yr, we measured NFV with bioelectrical impedance, internal jugular vein volume (IJVV) with ultrasound, and extravascular NFV (NFV EV ) as the difference between NFV and IJVV. Participants were randomly allocated to control and intervention, both of which were conducted on the same day. Measurements were made at baseline and every 5 min thereafter during control and intervention. During intervention, participants received 40 mmHg lower-body positive pressure (LBPP) when supine, followed by LBPP plus 10° Trendelenburg position, then LBPP when supine again, followed by recovery. During control, participants lay supine for equal time. LBPP and LBPP plus Trendelenburg position both increased NFV from baseline compared with control ( P < 0.001), with significant contributions from IJVV ( P < 0.001). Returning to supine with LBPP, IJVV returned to baseline, but NFV remained elevated because of accumulation of NFV EV. These findings suggest that contributions of IJVV to NFV are immediate but transient, whereas sustained elevation in NFV when supine is likely a result of NFV EV . These findings add new insights into the mechanism by which fluid accumulates in the neck by rostral fluid shift. NEW & NOTEWORTHY This study demonstrates that lying supine for 30 min as well as increased fluid shift out of the legs to simulate nocturnal rostral fluid shift causes fluid to accumulate mainly in the extravascular space of the neck rather than in the internal jugular veins. Therefore, in subjects without fluid-retaining states, extravascular neck fluid accumulation overnight might play a more significant role in the pathophysiology of upper-airway narrowing than intravascular fluid accumulation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.182
Threshold uncertainty score0.308

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.002
GPT teacher head0.245
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Applied PhysiologySame topicHemodynamic Monitoring and TherapyFrench-language works237,207