Deuterium isotope effect in fluorescence of gaseous oxazine dyes
Bibliographic record
Abstract
The increased utility of fluorescence-based methods in recent years has highlighted the need for brighter, more efficient fluorophores. In order to design these fluorophores, an improved fundamental understanding is necessary of the structural components that intrinsically effect fluorescence efficiency. Here, we characterize the intrinsic effects of deuteration on fluorescence from gaseous oxazine dyes, without the influence of dye-solvent interactions, by making use of an ion trap mass spectrometer that has been altered to enable optical measurements. Comparison of emission spectra of four oxazine dyes: cresyl violet, oxazine 4, oxazine 170, and darrow red, show little change in profile upon deuteration of amine groups. However, deuteration significantly increases the efficiency of fluorescence with an increase in fluorescence lifetime and brightness by 10-23% for the gaseous dyes. This increase is less than half that of the quantum yield increase observed in deuterated solution. This indicates the large fluorescence efficiency changes for the oxazine dyes in deuterated solution result from a combination of both intrinsic effects as well as substantial contribution from altered fluorophore-solvent interactions. The intrinsic effects behind increased lifetime upon deuteration are explored using time-dependent density functional theory (TD-DFT) calculations of potential energy surfaces (PESs) for ground and low lying excited electronic states. In accord with experimental observations, calculated S1-S0 emission spectra show only minor differences between deuterated and non-deuterated forms indicating that the deuteration does not affect the radiative channel appreciably. Relaxed PES scans along the torsional motions of the amino groups reveal that the increase in lifetimes upon deuteration is likely due to quenching of different radiationless changes channels in different oxazine dyes. Calculations suggest that tunneling to access twisted intramolecular charge transfer states in S1 is critical in several of the oxazines. However, in at least one of the dyes examined, the large isotope effect is more likely due to differences in intersystem crossing rates. Overall, this combined experimental and computational investigation elucidates the photophysics of a well-known fluorescent scaffold and provides insight into how small differences can dramatically affect fluorescence outcomes.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.001 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".