MétaCan
Menu
Back to cohort
Record W2917789037 · doi:10.1002/nbm.4073

VERDICT MRI validation in fresh and fixed prostate specimens using patient‐specific moulds for histological and MR alignment

2019· article· en· W2917789037 on OpenAlexaff
Colleen Bailey, Roger Bourne, Bernard Siow, Edward W. Johnston, Mrishta Brizmohun Appayya, Hayley Pye, Susan Heavey, Thomy Mertzanidou, Hayley C. Whitaker, Alex Freeman, Dominic Patel, Greg Shaw, Ashwin Sridhar, David J. Hawkes, Shonit Punwani, Daniel C. Alexander, Eleftheria Panagiotaki

Bibliographic record

VenueNMR in Biomedicine · 2019
Typearticle
Languageen
FieldMedicine
TopicAdvanced Neuroimaging Techniques and Applications
Canadian institutionsSunnybrook Hospital
FundersProgramme Grants for Applied ResearchNational Health and Medical Research CouncilCancer Research UKProstate Cancer UKMedical Research CouncilEngineering and Physical Sciences Research CouncilNational Institute for Health and Care ResearchUniversity College London
KeywordsHistologyEx vivoDiffusion MRIProstatectomyVerdictFixation (population genetics)ProstatePathologyAnatomyMedicineBiomedical engineeringChemistryMaterials scienceBiologyMagnetic resonance imagingIn vivoRadiologyInternal medicine

Abstract

fetched live from OpenAlex

The VERDICT framework for modelling diffusion MRI data aims to relate parameters from a biophysical model to histological features used for tumour grading in prostate cancer. Validation of the VERDICT model is necessary for clinical use. This study compared VERDICT parameters obtained ex vivo with histology in five specimens from radical prostatectomy. A patient-specific 3D-printed mould was used to investigate the effects of fixation on VERDICT parameters and to aid registration to histology. A rich diffusion data set was acquired in each ex vivo prostate before and after fixation. At both time points, data were best described by a two-compartment model: the model assumes that an anisotropic tensor compartment represents the extracellular space and a restricted sphere compartment models the intracellular space. The effect of fixation on model parameters associated with tissue microstructure was small. The patient-specific mould minimized tissue deformations and co-localized slices, so that rigid registration of MRI to histology images allowed region-based comparison with histology. The VERDICT estimate of the intracellular volume fraction corresponded to histological indicators of cellular fraction, including high values in tumour regions. The average sphere radius from VERDICT, representing the average cell size, was relatively uniform across samples. The primary diffusion direction from the extracellular compartment of the VERDICT model aligned with collagen fibre patterns in the stroma obtained by structure tensor analysis. This confirmed the biophysical relationship between ex vivo VERDICT parameters and tissue microstructure from histology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.008

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.062
GPT teacher head0.347
Teacher spread0.285 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations38
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueNMR in BiomedicineSame topicAdvanced Neuroimaging Techniques and ApplicationsFrench-language works237,207