MétaCan
Menu
Back to cohort
Record W2918761742 · doi:10.1117/12.2510430

Investigation of calibration-based projection domain dual energy decomposition CBCT technique for brain radiotherapy applications

2019· article· en· W2918761742 on OpenAlexaff
Shailaja Sajja, Mark Ruschin, Young Lee, SayedMasoud Hashemi, Håkan Nordström, Markus Eriksson, Christopher Huynh, James G. Mainprize, A. Nico, Arjun Sahgal, F Yin

Bibliographic record

VenueMedical Imaging 2019: Physics of Medical Imaging · 2019
Typearticle
Languageen
FieldEngineering
TopicAdvanced X-ray and CT Imaging
Canadian institutionsUniversity of TorontoSunnybrook Hospital
Fundersnot available
KeywordsImaging phantomMaterials scienceMonochromatic colorProjection (relational algebra)CalibrationOpticsComputer scienceBiomedical engineeringPhysicsAlgorithmMedicine

Abstract

fetched live from OpenAlex

The purpose of the present study was to develop and evaluate a practical dual-energy imaging approach for enhancing on-board cone-beam CT (CBCT) image quality for brain radiotherapy applications. The proposed primary technique involves a projection domain calibration procedure. In-house fabricated aluminum and acrylic step wedges were stacked and oriented orthogonally to each other to produce 72 unique combinations of two-material path lengths, i.e. 8 acrylic steps × 9 aluminum steps. High (120 kV) and low (70 kV) energy projections were acquired of the step wedges and a 3rd order polynomial fit was used to map the log-normalized projection intensities to the known acrylic and aluminum thicknesses. The subsequent model was tested on two phantoms: 1) in-house DE phantom with PMMA background and calcium inserts of different concentrations (5 mg/mL, 200 mg/mL and 400 mg/mL) and 2) a RANDO head phantom. The decomposed projections were reconstructed separately as aluminum-only and acrylic-only reconstructions. In addition, virtual monochromatic projections (VMPs) obtained by combining the aluminum-only and acrylic-only projections were reconstructed at different keVs. A quantitative improvement was observed in the SDNR (signal difference to noise ratios) of the calcium inserts using Aluminum-reconstructions and synthesized VMPs (40 to 100 keV) compared to the single energy reconstructions. A reduction in beam hardening was observed as well. In addition, a qualitative improvement in soft-tissue visualization was observed with the RANDO phantom reconstructions. The findings indicate the potential of dual energy CBCT images: material specific images as well as VMPs for improved CBCT-based image guidance. The present approach can readily be applied on existing commercial systems and a feasibility study on patients is a worthwhile investigation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.930
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.005
GPT teacher head0.265
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designSimulation or modeling
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueMedical Imaging 2019: Physics of Medical ImagingSame topicAdvanced X-ray and CT ImagingFrench-language works237,207