MétaCan
Menu
Back to cohort
Record W2918885402 · doi:10.1002/acm2.12548

Seasonal variations in measurements of linear accelerator output

2019· article· en· W2918885402 on OpenAlexaff
S Bartolac, Robert K. Heaton, Bernhard D. Norrlinger, D. Létourneau

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2019
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsPrincess Margaret Cancer Centre
Fundersnot available
KeywordsDosimeterLinear particle acceleratorRelative humidityEnvironmental scienceIonization chamberHumidityNuclear medicineDosimetryStatisticsMeteorologyMathematicsPhysicsMedicineIonOptics

Abstract

fetched live from OpenAlex

PURPOSE: Seasonal trends in linear accelerator output have been reported by at least one institution and data have suggested that they may be present at our center as well. The purpose of this work was to characterize these trends and determine whether local environmental conditions within the treatment rooms may be impacting the linear accelerators and/or the quality control (QC) dosimeter. METHODS: Runtime plots of daily output data, acquired using an in-house ion chamber-based device, over 3 yr and for 15 linear accelerators of different makes and models were reviewed and evaluated. Environmental conditions were monitored prospectively in a representative treatment room for approximately 9 months and evaluated for correlations with output trends. Independent measures of output using daily MV portal images were compared with output measurements using the ion chamber-based device. A separate controlled experiment probing the response of the in-house dosimeter to humidity changes over time was also carried out using a constant current source and a small enclosure. RESULTS: Runtime plots of output revealed sinusoidal, seasonal variations that were consistent across all treatment units, irrespective of manufacturer, model, or age of machine. The amplitude of the variation was on the order of 1% and maintained a yearly period. The independent measure of output using MV portal images did not corroborate the seasonal trends observed with the daily QC dosimeter. Based on the controlled experiment, the QC dosimeter was found to have a dependence on relative humidity changes, decreasing 1% in output per 30% increase in relative humidity. CONCLUSIONS: Results confirm the presence of underlying seasonal variations in measured output from the linear accelerators. The findings identify humidity impact on the measurement device as the underlying cause of the cyclical changes and not the accelerators themselves. These results could help minimize unwarranted machine servicing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.546
Threshold uncertainty score0.552

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.054
GPT teacher head0.375
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207