MétaCan
← all works

On osseointegration in relation to implant surfaces

2019· review· en· 355 citations· W2919469171 on OpenAlex· 10.1111/cid.12742

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian venueIt was published in a Canadian venue.

No Canadian affiliation. An affiliation-only frame — the usual design — would never have seen this work. It is one of the works that make the case for inverting the frame.

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.294
GPT teacher head0.552
Teacher spread
0.258 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

BACKGROUND: The understanding of mechanisms of osseointegration as well as applied knowledge about oral implant surfaces are of paramount importance for successful clinical results. PURPOSE: The aim of the present article is to present an overview of osseointegration mechanisms and an introduction to surface innovations with relevance for osseointegration that will be published in the same supplement of Clinical Implant Dentistry and Related Research. MATERIALS AND METHODS: The present article is a narrative review of some osseointegration and implant surface-related details. RESULTS AND CONCLUSIONS: Osseointegration has a changed definition since it is realized today that oral implants are but foreign bodies and that this fact explains osseointegration as a protection mechanism of the tissues. Given adequate stability, bone tissue is formed around titanium implants to shield them from the tissues. Oral implant surfaces may be characterized by microroughness and nanoroughness, by surface chemical composition and by physical and mechanical parameters. An isotropic, moderately rough implant surface such as seen on the TiUnite device has displayed improved clinical results compared to previously used minimally rough or rough surfaces. However, there is a lack of clinical evidence supporting any particular type of nanoroughness pattern that, at best, is documented with results from animal studies. It is possible, but as yet unproven, that clinical results may be supported by a certain chemical composition of the implant surface. The same can be said with respect to hydrophilicity of implant surfaces; positive animal data may suggest some promise, but there is a lack of clinical evidence that hydrophilic implants result in improved clinical outcome of more hydrophobic surfaces. With respect to mechanical properties, it seems obvious that those must be encompassing the loading of oral implants, but we need more research on the mechanically ideal implant surface from a clinical aspect.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
Clinical Implant Dentistry and Related Research
Topic
Dental Implant Techniques and Outcomes
Field
Dentistry
Canadian institutions
Funders
Keywords
OsseointegrationImplantDentistryDental implantBiomedical engineeringMaterials scienceMedicineSurgery
Has abstract in OpenAlex
yes