MétaCan
Menu
Back to cohort
Record W2919910165 · doi:10.1111/hdi.12738

Clinical hemodialysis experience with percutaneous arteriovenous fistulas created using the Ellipsys® vascular access system

2019· article· en· W2919910165 on OpenAlexvenueno aff
Hedia Hebibi, Jedjiga Achiche, Gilbert Franco, Jacques Rottembourg

Bibliographic record

VenueHemodialysis International · 2019
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsnot available
Fundersnot available
KeywordsMedicineArteriovenous fistulaHemodialysisPercutaneousSurgeryBrachial arteryRadial arteryFistulaArteriovenous AnastomosisForearmHemodialysis accessAnastomosisArteryInternal medicineVascular accessBlood pressure

Abstract

fetched live from OpenAlex

INTRODUCTION: The aim of this study is to report our clinical hemodialysis experience using a percutaneous arteriovenous fistula (pAVF) created with the Ellipsys® vascular access system. This pAVF device creates a permanent AVF anastomosis between the proximal radial artery (PRA) and the deep communicating vein (DCV) in the proximal forearm. METHODS: The medical records of all patients with a pAVF were retrospectively reviewed. The clinical data analyzed included reliability of pAVF use, quality of dialysis, rate and success of puncture, and pAVF related complications, along with incidence of subsequent interventions. FINDINGS: Between May 2017 and November 2018, 34 patients had a pAVF created with technical success in 33 patients (97%). Twenty-eight out of 34 (82%) patients had successful two-needle cannulation within 10 days to 6 weeks after pAVF creation. The mean Kt/v was 1.6 (1.2-2) and the average recirculation was 10%. Fifteen patients (44%) needed no further access intervention. Twelve patients (35%) required an additional procedure to assist maturation of the pAVF in order to facilitate puncture. The average blood flow measured at the brachial artery, before the first cannulation, was 850 ml/min. From causes unrelated to the procedure, four patients died during the follow-up study. Two patients required revision to a surgical AVF. None of the pAVFs developed aneurysmal degeneration steal syndrome, or high access flow related issues. DISCUSSION: The Ellipsys® pAVF offers a safe and functional vascular access for hemodialysis. Advantages included prompt access maturation, avoidance of high flow AVFs, and a simple nonsurgical procedure with high patient satisfaction. Functional outcomes are equivalent and likely better than surgical fistulas. There appears to be less aneurysmal degeneration and need for future re-intervention. Objective dialysis parameters indicate excellent quality of hemodialysis for the patient.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.058
GPT teacher head0.388
Teacher spread0.330 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations40
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueHemodialysis InternationalSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207