MétaCan
Menu
Back to cohort

Ten-Year Clinical Outcomes From a Trial of Three Limus-Eluting Stents With Different Polymer Coatings in Patients With Coronary Artery Disease

2019· article· en· W2922359749 on OpenAlexaboutno aff
Sebastian Kufner, Michael Joner, Anna Thannheimer, Petra Hoppmann, Tareq Ibrahim, Katharina Mayer, Salvatore Cassese, Karl‐Ludwig Laugwitz, Heribert Schunkert, Adnan Kastrati, Robert A. Byrne

Bibliographic record

VenueCirculation · 2019
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsnot available
FundersEuropean Society of CardiologyBoston Scientific CorporationB. Braun MelsungenAstraZenecaServierAmgen
KeywordsMedicineStentMyocardial infarctionInternal medicineSirolimusCoronary artery diseaseTarget lesionCardiologySurgeryThrombosisDrug-eluting stentEverolimusAdverse effectRestenosisPercutaneous coronary intervention

Abstract

fetched live from OpenAlex

BACKGROUND: New-generation drug-eluting stents offer the potential for enhanced late outcomes in comparison with early generation drug-eluting stents. However, assessment of extended long-term outcomes for these devices is lacking, especially regarding the comparison between new-generation drug-eluting stents with biodegradable or permanent polymers. The aim of this study is to compare the efficacy and safety of biodegradable polymer-based sirolimus-eluting stents (BP-SES; Yukon Choice PC) versus permanent polymer-based everolimus-eluting stents (PP-EES; Xience) versus early generation permanent polymer-based sirolimus-eluting stents (PP-SES; Cypher) at 10-year follow-up. METHODS: Overall, 2603 patients were randomized to treatment with BP-SES (n=1299), PP-EES (n=652), or PP-SES (n=652). The primary end point of this analysis was major adverse cardiac event, the composite of death, myocardial infarction, or target lesion revascularization. The main secondary end point of interest was definite/probable stent thrombosis. Follow-up at 10 years was available in 83% of the study patients. RESULTS: The 10-year incidence of major adverse cardiac event (BP-SES 47.7% versus PP-EES 46.0% versus PP-SES 54.9%, P=0.003) and mortality (BP-SES 31.8% versus PP-EES 30.3% versus PP-SES 37.2%, P=0.02) was different among the groups. Definite/probable stent thrombosis was not significantly different among the groups (BP-SES 1.8% versus PP-EES 2.5% versus PP-SES 3.7%, P=0.09). Definite stent thrombosis was significantly different among the groups (BP-SES 1.1% versus PP-EES 0.8% versus PP-SES 2.4%, P=0.03). There were no significant differences between BP-SES and PP-EES. CONCLUSIONS: In this unique long-term outcome analysis, BP-SES and PP-EES showed comparable clinical outcomes out to 10 years. PP-SES had higher rates of major adverse cardiac events and definite stent thrombosis. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov . Unique identifier: NCT00598676.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.019

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0020.003
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.034
GPT teacher head0.288
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations152
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueCirculationSame topicCoronary Interventions and DiagnosticsFrench-language works237,207