MétaCan
Menu
Back to cohort
Record W2922944710 · doi:10.1177/0954411919837302

Proposed percutaneous aortic valve prosthesis made of cryogel

2019· article· en· W2922944710 on OpenAlexafffund
Hadi Mohammadi, Dylan Goode, Guy Fradet, Kibret Mequanint

Bibliographic record

VenueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsWestern UniversityUniversity of British Columbia, Okanagan CampusUniversity of British Columbia
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of British Columbia
KeywordsAortic valveMaterials sciencePercutaneousHeart valveBiomedical engineeringMedicineSurgery

Abstract

fetched live from OpenAlex

Transcatheter heart valves are promising for high-risk patients. Generally, their leaflets are made of pericardium stented in a Nitinol basket. Despite their relative success, they are associated with significant complications such as valve migration, implantation risks, stroke, coronary obstruction, myocardial infraction, acute kidney injury (which all are due to the release of detached solid calcific pieces in to the blood stream) and expected issues existing with tissue valves such as leaflet calcification. This study is an attempt to fabricate the first ever polymeric percutaneous valves made of cryogel following the geometry and mechanical properties of porcine aortic valve to address some of the above-mentioned shortcomings. A novel, one-piece, tricuspid percutaneous valve, consisting of leaflets made entirely from the hydrogel, polyvinyl alcohol cryogel reinforced by bacterial cellulose natural nanocomposite, attached to a Nitinol basket was developed and demonstrated. Following the natural geometry of the valve, a novel approach was applied based on the revolution about an axis of a hyperboloid shape. The geometry was modified based on avoiding sharp warpage of leaflets and removal of the central opening orifice area of the valve when valve is fully closed using the finite element analysis. The modified geometry was replaced by a cloud of (control) points and was essentially converted to Bezier surfaces for further adjustment. A cavity mold was then designed and fabricated to form the valve. The fabricated valve was sewn into the Nitinol basket which is covered by Dacron cloth. The models presented in this study merit further development and revisions for both aortic and mitral positions.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.261
Teacher spread0.252 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueProceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in MedicineSame topicCardiac Valve Diseases and TreatmentsFrench-language works237,207