MétaCan
Menu
Back to cohort
Record W2926943402 · doi:10.1088/1361-6560/ab1503

A study of inter-crystal scatter in dual-layer offset scintillator arrays for brain-dedicated PET scanners

2019· article· en· W2926943402 on OpenAlexafffund
Mohammadreza Teimoorisichani, Andrew L. Goertzen

Bibliographic record

VenuePhysics in Medicine and Biology · 2019
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsUniversity of Manitoba
FundersNatural Sciences and Engineering Research Council of CanadaUniversity of Manitoba
KeywordsDetectorScintillationImaging phantomScintillatorDual layerOpticsScatteringCRFSOffset (computer science)Layer (electronics)Crystal (programming language)Materials sciencePhysicsCoincidenceComputer scienceArtificial intelligenceNanotechnologyMedicine

Abstract

fetched live from OpenAlex

A dual-layer offset (DLO) detector enables depth-of-interaction (DOI) through light sharing between two layers of scintillation arrays with a single-ended readout (SER) scheme. However, the SER scheme in DLO detectors may lead to a layer misassignment when inter-crystal scattering occurs. The aim of this work is to study inter-crystal scattering and evaluate the effects of layer misidentifications in DLO detectors on the performance of scanners suitable for a brain-dedicated PET insert. The influence of layer misidentification on the coincidence response functions (CRFs) of 3 different DLO detectors with total/front/back layer thicknesses of 15/6/9 mm, 20/8/12 mm, and 25/7.5/17.5 mm and a crystal width of about 3 mm was studied through Monte Carlo simulations. To overcome layer misidentification, we studied a practical DLO detector design in which each layer can be read out independently through a discrete-layer readout (DLR) scheme where light sharing between the layers is avoided. The CRFs of the mentioned DLO detectors assuming SER and DLR were analyzed. To evaluate the effects of layer misidentification on image quality, images of a Derenzo-like phantom were also reconstructed for all DLO and their equivalent single layer PET scanners. Our analysis showed that layer misassignments due to inter-crystal scatter in DLO detectors mainly has effect on the full-width at tenth maximum of the CRFs. According to the reconstructed images of the phantom, no significant improvements in the quality of the images were seen when SER was replaced with DLR. The results suggest that layer misidentification in DLO detectors does not play an important role in the quality of the PET images.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.007

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.153
GPT teacher head0.429
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2019
Admission routes2
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicMedical Imaging Techniques and ApplicationsFrench-language works237,207