fetched live from OpenAlex

The use of treatment plan characteristics to predict patient-specific quality assurance (QA) measurement results has recently been reported as a strategy to help facilitate automated pre-treatment verification workflows or to provide a virtual assessment of delivery quality. The goal of this work is to investigate the potential of using treatment plan characteristics and linac performance metrics (i.e. quality control test results) in combination with machine learning techniques to predict the results of VMAT patient-specific QA measurements. Using features that describe treatment plan complexity and linac performance metrics, we trained a linear support vector classifier (SVC) to classify the results of VMAT patient-specific QA measurements. The 'targets' in this model were simple classes representing median dose difference between measured and expected dose distributions-'hot' if the median dose deviation was >1%, 'cold' if it was <-1%, and 'normal' if it was within ±1%. A total of 1620 unique patient-specific QA measurements were available for model development and testing. 75% of the data were used to develop and cross-validate the model, and the remaining 25% were used for an independent assessment of model performance. For the model development phase, a recursive feature elimination (RFE) cross-validation technique was used to eliminate unimportant features. Model performance was assessed using receiver operator characteristic (ROC) curve metrics. Of the ten features found to be most predictive of patient-specific QA measurement results, half were derived from treatment plan characteristics and half from quality control (QC) metrics characterizing linac performance. The model achieved a micro-averaged area under the ROC curve of 0.93, and a macro-averaged area under the ROC curve of 0.88. This work demonstrates the potential of using both treatment plan characteristics and routine linac QC results in the development of machine learning models for VMAT patient-specific QA measurements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.536
Threshold uncertainty score0.582

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.150
GPT teacher head0.365
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations76
Published2019
Admission routes1
Has abstractyes

Explore more

Same venuePhysics in Medicine and BiologySame topicAdvanced Radiotherapy TechniquesFrench-language works237,207