MétaCan
Menu
Back to cohort
Record W2932454984 · doi:10.1097/hp.0000000000001059

Demonstrating Compliance With Proposed Reduced Lens of Eye Dose Limits in Nuclear Medicine Settings

2019· article· en· W2932454984 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueHealth Physics · 2019
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsUniversity of ManitobaHealth Sciences Centre
Fundersnot available
KeywordsEye lensDosimeterMedicineRadiation protectionLens (geology)Equivalent doseNuclear medicineMedical physicsDosimetryPhysicsOptics

Abstract

fetched live from OpenAlex

Based on ongoing research on ionizing radiation thresholds for cataracts, the International Commission on Radiological Protection has proposed new guidelines lowering the annual occupational lens of eye dose limit from 150 mSv to 20 mSv. The International Atomic Energy Agency has operationalized these new guidelines. Subsequently, national/regional radiation protection regulators are reviewing their lens of eye dose limits with an aim of moving towards the proposed new limits, resulting in licensees having to demonstrate compliance. In health care settings, fluoroscopic interventional practices generally have higher lens of eye doses and nuclear medicine settings generally have lower doses. A prospective cohort (n = 19) of nuclear medicine technologists wore dedicated lens of eye dosimeters for a 3 mo period synchronized with their body dosimeter schedules. The lens of eye dosimeters were validated to have a linear response in the anticipated dose ranges. The participants worked in a relatively high-volume nuclear medicine practice, which included general and cardiac, positron emission tomography/computed tomography, radiopharmacy, and cyclotron operations. The annualized dose ranges were 0.0-3.68 mSv (lens of eye) and 0.48-4.72 mSv (whole body). There was a good correlation between lens of eye and body dosimeter readings (R = 0.67). There were no significant differences in lens of eye dose by work type, worker sex, or side on which the dosimeter was worn. The findings should be generalizable to other similar practices, especially in North America, and should be sufficient to demonstrate regulatory compliance in nuclear medicine settings with the proposed new lens of eye dose limits.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.356
Threshold uncertainty score0.365

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.344
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it