Methodological consensus on clinical proton MRS of the brain: Review and recommendations

2019· review· en· W2932841619 on OpenAlexaff
Martin Wilson, Ovidiu C. Andronesi, Peter B. Barker, Robert Bartha, Alberto Bizzi, Patrick J. Bolan, Kevin M. Brindle, In‐Young Choi, Cristina Cudalbu, Ulrike Dydak, Uzay E. Emir, R. Gilberto González, Stephan Gruber, Rolf Gruetter, Rakesh K. Gupta, Arend Heerschap, A Henning, Hoby P. Hetherington, Petra S. Hüppi, Ralph E. Hurd, Kejal Kantarci, Risto A. Kauppinen, Dennis W. J. Klomp, Roland Kreis, Marijn J. Kruiskamp, Martin O. Leach, Alexander Lin, Peter R. Luijten, Małgorzata Marjańska, Andrew A. Maudsley, Dieter J. Meyerhoff, Carolyn E. Mountford, Paul G. Mullins, James B. Murdoch, Sarah J. Nelson, Ralph Noeske, Gülin Öz, Julie W. Pan, Andrew C. Peet, Harish Poptani, Stefan Posse, Eva‐Maria Ratai, Nouha Salibi, Tom W. J. Scheenen, Ian C. P. Smith, Brian J. Soher, Ivan Tkáč, Daniel B. Vigneron, Franklyn A. Howe

Bibliographic record

VenueMagnetic Resonance in Medicine · 2019
Typereview
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsNational Research Council Institute for BiodiagnosticsWestern University
FundersEunice Kennedy Shriver National Institute of Child Health and Human DevelopmentNational Institute of Biomedical Imaging and BioengineeringNational Institute of Neurological Disorders and StrokeUniversity of California, San FranciscoCancer Research UK
KeywordsMedicineMedical physics

Abstract

fetched live from OpenAlex

Proton MRS (1H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good‐quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi‐adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.016
metaresearch head score (Gemma)0.033
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.016
Threshold uncertainty score0.084

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0160.033
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0060.004
Bibliometrics0.0100.008
Science and technology studies0.0010.001
Scholarly communication0.0030.006
Open science0.0050.003
Research integrity0.0040.004
Insufficient payload (model declined to judge)0.0060.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.453
GPT teacher head0.567
Teacher spread0.113 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations489
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207