MétaCan
Menu
Back to cohort
Record W2936439868 · doi:10.1186/s12968-019-0522-y

Quantification in cardiovascular magnetic resonance: agreement of software from three different vendors on assessment of left ventricular function, 2D flow and parametric mapping

2019· article· en· W2936439868 on OpenAlexfundno aff
Leonora Zange, Fabian Muehlberg, Edyta Błaszczyk, Susanne Schwenke, Julius Traber, Stephanie Funk, Jeanette Schulz‐Menger

Bibliographic record

VenueJournal of Cardiovascular Magnetic Resonance · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiac Imaging and Diagnostics
Canadian institutionsnot available
FundersCircle Cardiovascular ImagingSiemens Healthineers
KeywordsMedicineAngiologyMagnetic resonance imagingEjection fractionStroke volumeSoftwareNuclear medicineData miningRadiologyComputer scienceCardiologyHeart failure

Abstract

fetched live from OpenAlex

BACKGROUND: Quantitative results of cardiovascular magnetic resonance (CMR) image analysis influence clinical decision making. Image analysis is performed based on dedicated software. The manufacturers provide different analysis tools whose algorithms are often unknown. The aim of this study was to evaluate the impact of software on quantification of left ventricular (LV) assessment, 2D flow measurement and T1- and T2-parametric mapping. METHODS: , Siemens Healthineers: Argus, Medis: Qmass/Qflow) by one reader blinded to former results. Cine steady state free precession short axis images were analyzed regarding LV ejection fraction (EF), end-systolic and end-diastolic volume (ESV, EDV) and LV mass. Phase-contrast magnetic resonance images were evaluated for forward stroke volume (SV) and peak velocity (Vmax). Pixel-wise generated native T1- and T2-maps were used to assess T1- and T2-time. Forty-five data sets were evaluated twice (15 per software) for intraobserver analysis. Equivalence was considered if the confidence interval of a paired assessment of two sofware was within a tolerance interval defined by ±1.96 highest standard deviation obtained by intraobserver analysis. RESULTS: For each parameter, thirty data sets could be analyzed with all three software. All three software (A/B, A/C, B/C) were considered equivalent for LV EF, EDV, ESV, mass, 2D flow SV and T2-time. Differences between software were detected in flow measurement for Vmax and in parametric mapping for T1-time. For Vmax, equivalence was given between software A and C and for T1-time equivalence was given between software B and C. CONCLUSION: Software had no impact on quantitative results of LV assessment, T2-time and SV based on 2D flow. In contrast to that, Vmax and T1-time may be influenced by software. CMR reports should contain the name and version of the software applied for image analysis to avoid misinterpretation upon follow-up and research examinations. TRIAL REGISTRATION: ISRCTN12210850 . Registered 14 July 2017, retrospectively registered.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.043
metaresearch head score (Gemma)0.070
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.043
Threshold uncertainty score0.230

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0430.070
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.002
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.233
Teacher spread0.221 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations54
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular Magnetic ResonanceSame topicCardiac Imaging and DiagnosticsFrench-language works237,207