MétaCan
Menu
Back to cohort
Record W2937377430 · doi:10.3390/s19081885

Validity of Wearable Sensors at the Shoulder Joint: Combining Wireless Electromyography Sensors and Inertial Measurement Units to Perform Physical Workplace Assessments

2019· article· en· W2937377430 on OpenAlexafffund
Isabelle Poitras, Mathieu Bielmann, Alexandre Campeau‐Lecours, Catherine Mercier, Laurent J. Bouyer, Jean‐Sébastien Roy

Bibliographic record

VenueSensors · 2019
Typearticle
Languageen
FieldEngineering
TopicMuscle activation and electromyography studies
Canadian institutionsUniversité LavalCentre for Interdisciplinary Research in Rehabilitation
FundersNatural Sciences and Engineering Research Council of CanadaCanada First Research Excellence Fund
KeywordsWearable computerInertial measurement unitElectromyographyAccelerometerUnits of measurementWirelessJoint (building)Inertial frame of referenceComputer scienceEngineeringPhysical medicine and rehabilitationArtificial intelligenceMedicineTelecommunicationsEmbedded systemPhysicsStructural engineering

Abstract

fetched live from OpenAlex

Background: Workplace adaptation is the preferred method of intervention to diminish risk factors associated with the development of work-related shoulder disorders. However, the majority of the workplace assessments performed are subjective (e.g., questionnaires). Quantitative assessments are required to support workplace adaptations. The aims of this study are to assess the concurrent validity of inertial measurement units (IMUs; MVN, Xsens) in comparison to a motion capture system (Vicon) during lifting tasks, and establish the discriminative validity of a wireless electromyography (EMG) system for the evaluation of muscle activity. Methods: Sixteen participants performed 12 simple tasks (shoulder flexion, abduction, scaption) and 16 complex lifting tasks (lifting crates of different weights at different heights). A Delsys Trigno EMG system was used to record anterior and middle deltoids’ EMG activity, while the Xsens and Vicon simultaneously recorded shoulder kinematics. Results: For IMUs, correlation coefficients were high (simple task: >0.968; complex task: >0.84) and RMSEs were low (simple task: <6.72°; complex task: <11.5°). For EMG, a significant effect of weight, height and a weight x height interaction (anterior: p < 0.001; middle: p < 0.03) were observed for RMS EMG activity. Conclusions: These results suggest that wireless EMG and IMUs are valid units that can be used to measure physical demand in workplace assessments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.211
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.249
Teacher spread0.218 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations69
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueSensorsSame topicMuscle activation and electromyography studiesFrench-language works237,207