MétaCan
Menu
Back to cohort
Record W2937415012 · doi:10.1148/radiol.2019181830

CT of Kidney Volume in Autosomal Dominant Polycystic Kidney Disease: Accuracy, Reproducibility, and Radiation Dose

2019· article· en· W2937415012 on OpenAlexafffund
Micheli Bevilacqua, Cameron Hague, Alexandra Romann, Hana Sheitt, Dragoş M. Vasilescu, Tae Won Yi, Adeera Levin

Bibliographic record

VenueRadiology · 2019
Typearticle
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicGenetic and Kidney Cyst Diseases
Canadian institutionsUniversity of British Columbia
FundersUniversity of British Columbia
KeywordsMedicineIntraclass correlationReproducibilityNuclear medicineStandard deviationStandard errorRadiologyGold standard (test)Autosomal dominant polycystic kidney diseaseMathematicsCystStatistics

Abstract

fetched live from OpenAlex

Background Total kidney volume (TKV) assessment is valuable in autosomal dominant polycystic kidney disease (ADPKD) but the reference standard method of MRI planimetry requires access to MRI and time-consuming interpretation. Purpose To determine whether accurate TKV measurements comparable to the resource-intensive reference standard of MRI planimetry can be obtained by using alternate methods including dose-reducing CT protocols and time-saving measurement equations. Materials and Methods In this prospective study conducted September 2016 to June 2017, adult participants with ADPKD underwent one MRI and two CT examinations. Low-dose (LD) and ultra-low-dose (ULD) CT examinations were performed with radiation doses 1.4 and 2.6 times lower, respectively, than the authors’ institution’s standard abdomen and pelvis CT. ULD CT examinations were reconstructed via model-based iterative reconstruction. Three TKV measurement equations were applied to all image sets, and MRI manual planimetry was the reference standard. Spearman correlation with the reference standard, simple linear regression, and root mean square error (RMSE) calculation analyzed accuracy of these methods; intraclass correlation coefficient examined reproducibility. Results Thirty participants (mean age, 41 years; age range, 24–67 years) had a mean TKV of 1368.9 mL ± 1146.13 (standard deviation). The ULD and LD CT protocols had median dose-length product of 58.8 and 115.5 mGy ∙ cm, respectively (P = .01), and CT dose index of 1.2 and 3.9 mGy, respectively (P < .001). All imaging modalities and measurement equations had excellent correlation with the reference standard (r2 > 0.98). RMSE ranged from 80.5 to 157.3 mL (5.9%–11.5% of mean TKV). Intraclass correlation coefficients were greater than 0.98 for all methods. Mean measurement times for the ellipsoid method ranged from 4.6 to 5.2 minutes compared with a mean of 27.7 minutes (range, 14–60 minutes) for manual planimetry. Conclusion Accurate and reproducible total kidney volume measurements comparable to the reference standard of MRI planimetry can be obtained by using a dose-minimizing ultra-low-dose CT protocol and volume measurement based on discrete linear measurements. © RSNA, 2019 Online supplemental material is available for this article.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.004
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.442
Threshold uncertainty score0.692

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.004
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.242
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueRadiologySame topicGenetic and Kidney Cyst DiseasesFrench-language works237,207