MétaCan
Menu
Back to cohort

Quadrupole Ion Trap Mass SpectrometerUpdate based on the original article by Raymond March, <i>Encyclopedia of Analytical Chemistry</i> , © 2000, John Wiley &amp; Sons, Ltd.

2012· other· en· W2939173797 on OpenAlexaff
Raymond E. March

Bibliographic record

VenueEncyclopedia of Analytical Chemistry · 2012
Typeother
Languageen
FieldChemistry
TopicMass Spectrometry Techniques and Applications
Canadian institutionsTrent University
Fundersnot available
KeywordsQuadrupole ion trapIon trapIonMass spectrometryChemistryQuadrupole mass analyzerIon trappingTriple quadrupole mass spectrometerQuadrupoleAnalytical Chemistry (journal)Atomic physicsMass spectrumHybrid mass spectrometerTandem mass spectrometryPhysicsSelected reaction monitoring

Abstract

fetched live from OpenAlex

Abstract The quadrupole ion trap (QIT) is constructed of three electrodes that, when held at appropriate potentials, cause the formation of a trapping pseudo‐potential well so that charged particles, or gaseous ions, may be confined or stored for long periods of time. The two end‐cap electrodes resemble saucers while the ring electrode resembles a napkin ring; all of the electrodes are of hyperbolic geometry. The ion trap itself functions as a mass spectrometer when the ion‐confining conditions are modified such that ions are ejected mass‐selectively from the trapping potential well. As ions of successive mass/charge ratios are ejected in turn from the ion trap, they impinge upon an external detector whereby ion signals are created in proportion to the ion number of each species; in this manner, a mass spectrum is generated. The QITMS (quadrupole ion trap mass spectrometer) is an extraordinary instrument in that it is physically small (the entire electrode assembly can be held in the palm of one's hand) compared with magnetic and electric sector instruments, it is relatively inexpensive, it is one of the most, if not the most, sensitive mass spectrometers and, since several mass‐selective operations can be carried in succession, the ion trap can function as a tandem mass spectrometer. Tandem mass spectrometric operation is described as (MS) n . With the QITMS, (MS) n is carried out in time in the same volume of space whereas (MS) n in sector instruments is carried out in space. With sector instruments, the maximum value of n is n = 4 yet with the ion trap, (MS) n where n = 4–6 can be carried out routinely and n = 13 has been achieved. The QITMS shares several similarities with the ion cyclotron resonance mass spectrometer yet the cost of the former is about one‐tenth that of the latter. One striking difference between the QITMS and all other mass spectrometers is that the QITMS operates at a pressure of 10 −3 Torr compared with 10 −6 to 10 −9 Torr for other mass spectrometers. The theory of ion confinement and ion trajectory manipulation in the QITMS has been explained relatively simply so far. Since the theory differs widely from those of sector instruments and ion cyclotron resonance mass spectrometry (ICR/MS), it will not be familiar to those who have not had the opportunity to examine ion motion in quadrupole fields. Optimum operation of the QITMS is effected by collisional focusing of the ion cloud to the center of the ion trap under the influence of helium buffer gas. Since the movement of ions confined in the ion trap is periodic, the trajectories of collisionally focused ions can be expanded by resonance excitation effected by the imposition of supplementary radio frequency (rf) potentials of low amplitude to the end‐cap electrodes of the ion trap. This excitation operation permits isolation of selected ion species, by ejection of unwanted ion species, followed by selective ion/molecule reaction or by collision‐induced dissociation (CID) with subsequent mass analysis of the product/fragment ions formed. Sample calculations are given of all of the relevant trapping parameters. Applications of the QITMS as a single stage mass spectrometer and as a tandem mass spectrometer are discussed. The operation of the QITMS for the identification of dioxins and furans co‐eluting from a gas chromatograph is described. In addition, the application of chemical ionization (CI) for the identification of co‐eluting polychlorinated biphenyl (PCB) congeners is discussed. The QITMS is an extraordinary instrument that is capable of great sensitivity, high mass range and high mass resolution. Since the QITMS is compatible with methods for generating ions externally, such as electrospray ionization (ESI), its continued growth in many areas of mass spectrometry (MS) is assured. The structural details of the glycoprotein and the optical spectroscopy of stored ions are applications of the QITMS combined with ESI, while the ion trap in combination with a metal‐cluster aggregation source has been used for an electron diffraction study.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: Not applicable
GenreCandidate signal: Other · Consensus signal: none
Teacher disagreement score0.097
Threshold uncertainty score0.325

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0040.002
Science and technology studies0.0010.001
Scholarly communication0.0020.002
Open science0.0030.002
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0970.078

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.251
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreOther

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueEncyclopedia of Analytical ChemistrySame topicMass Spectrometry Techniques and ApplicationsFrench-language works237,207