MétaCan
Menu
Back to cohort
Record W2939933754 · doi:10.1002/jor.24294

Validation of In Vivo Linear and Volumetric Wear Measurement for Reverse Total Shoulder Arthroplasty Using Model‐Based Radiostereometric Analysis

2019· article· en· W2939933754 on OpenAlexafffund
Madeleine L. Van de Kleut, Xunhua Yuan, George S. Athwal, Matthew G. Teeter

Bibliographic record

VenueJournal of Orthopaedic Research® · 2019
Typearticle
Languageen
FieldMedicine
TopicShoulder Injury and Treatment
Canadian institutionsSt Joseph's Health CareLawson Health Research InstituteWestern University
FundersCanadian Institutes of Health ResearchWright Medical Group
KeywordsInsert (composites)Biomedical engineeringMaterials scienceArthroplastyImaging phantomOrthodonticsMedicineSurgeryNuclear medicineComposite material

Abstract

fetched live from OpenAlex

ABSTRACT Presently, polyethylene wear measurement of reverse total shoulder arthroplasty (rTSA) is restricted to in vitro, in silico, and retrieval analysis, with no method for the quantification of in vivo wear of well‐functioning implants. The purpose of this study was to validate the use of model‐based radiostereometric analysis (MBRSA) as a measurement tool for in vivo rTSA wear using a phantom setup. Six additively manufactured polyethylene inserts were fabricated, one unworn control and five to represent known wear patterns, and individually fit within the rTSA components. Each insert was imaged using standard radiostereometric techniques and analyzed using MBRSA. From the position and orientation estimation provided by MBRSA, a micro‐computed tomography model of the control insert was virtually placed within the metaphyseal tray. The apparent intersection of the glenosphere into the insert was recorded as wear. This method enables wear measurements with a linear precision of 0.21 mm and a bias of 0.36 ± 0.13 mm, and a volumetric precision of 49.3 mm3, with a bias of 48.9 ± 24.3 mm3. This technique allows for the in vivo measurement of polyethylene wear without the requirement of marker beads or baseline radiographs, expanding the potential for in vivo wear measurements to larger populations and retrospective analysis. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:1620–1627, 2019.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.005
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.018

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.005
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.138
GPT teacher head0.398
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Orthopaedic Research®Same topicShoulder Injury and TreatmentFrench-language works237,207