MétaCan
Menu
Back to cohort
Record W2942915869 · doi:10.18383/j.tom.2019.00001

Phantom Validation of DCE-MRI Magnitude and Phase-Based Vascular Input Function Measurements

2019· article· en· W2942915869 on OpenAlexafffund
Warren D. Foltz, Brandon Driscoll, Sangjune Laurence Lee, Krishna S. Nayak, Naren Nallapareddy, Ali Fatemi, Cynthia Ménard, Catherine Coolens, Caroline Chung

Bibliographic record

VenueTomography · 2019
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsPrincess Margaret Cancer CentreUniversity of TorontoCentre Hospitalier de l’Université de MontréalUniversity Health Network
FundersNatural Sciences and Engineering Research Council of CanadaPrincess Margaret Cancer Foundation
KeywordsFlip angleImaging phantomMagnetic resonance imagingMaterials scienceBiomedical engineeringVolumetric flow rateNuclear magnetic resonanceNuclear medicineMedicinePhysicsRadiologyMechanics

Abstract

fetched live from OpenAlex

Accurate, patient-specific measurement of arterial input functions (AIF) may improve model-based analysis of vascular permeability. This study investigated factors affecting AIF measurements from magnetic resonance imaging (MRI) magnitude (AIFMAGN) and phase (AIFPHA) signals, and compared them against computed tomography (CT) (AIFCT), under controlled conditions relevant to clinical protocols using a multimodality flow phantom. The flow phantom was applied at flip angles of 20° and 30°, flow rates (3–7.5 mL/s), and peak bolus concentrations (0.5–10 mM), for in-plane and through-plane flow. Spatial 3D-FLASH signal and variable flip angle T1 profiles were measured to investigate in-flow and radiofrequency-related biases, and magnitude- and phase-derived Gd-DTPA concentrations were compared. MRI AIF performance was tested against AIFCT via Pearson correlation analysis. AIFMAGN was sensitive to imaging orientation, spatial location, flip angle, and flow rate, and it grossly underestimated AIFCT peak concentrations. Conversion to Gd-DTPA concentration using T1 taken at the same orientation and flow rate as the dynamic contrast-enhanced acquisition improved AIFMAGN accuracy; yet, AIFMAGN metrics remained variable and significantly reduced from AIFCT at concentrations above 2.5 mM. AIFPHA performed equivalently within 1 mM to AIFCT across all tested conditions. AIFPHA, but not AIFMAGN, reported equivalent measurements to AIFCT across the range of tested conditions. AIFPHA showed superior robustness.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.013
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.005
Threshold uncertainty score0.025

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0050.013
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.307
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueTomographySame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207