MétaCan
Menu
Back to cohort
Record W2943513828 · doi:10.1109/iscas.2019.8702403

A 9.2-Gram Fully-Flexible Wireless Dry-Electrode Headband for Non-Contact Artifact-Resilient EEG Monitoring and Programmable Diagnostics

2019· article· en· W2943513828 on OpenAlexaff
Alireza Dabbaghian, Tayebeh Yousefi, Pooria Shafia, Syyeda Zainab Fatmi, Hossein Kassiri

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldNeuroscience
TopicEEG and Brain-Computer Interfaces
Canadian institutionsYork University
Fundersnot available
KeywordsComputer scienceWearable computerWirelessProgrammable-gain amplifierArtifact (error)Computer hardwareField-programmable gate arrayElectrical engineeringEmbedded systemBandwidth (computing)EngineeringAmplifierArtificial intelligenceTelecommunications

Abstract

fetched live from OpenAlex

An 8-channel wearable wireless device for surface EEG monitoring is presented. The entire multi-channel recording, quantization, and motion artifact removal is implemented on a 4-layer polyimide flexible substrate. The recording electrodes and active shielding are also integrated on the same substrate, yielding the smallest form factor compared to the state of the art. Thanks to the dry non-contact electrodes, the system is quickly mountable with minimal assistance required, making it an ideal frontal and temporal-lobe EEG monitoring device in emergency departments. The flexible main board is connected to a rechargeable battery on one end and to a 13×17mm2rigid board on the other end. The mini rigid board hosts a low-power programmable FPGA and a BLE 5.0 transceiver, which add diagnostic capability and wireless operation features to the device, respectively. The device performance in terms of voltage gain (260 V/V), bandwidth (DC-700 Hz), input-referred noise, motion artifact removal, and wireless communication throughput (up to 1Mbps) is experimentally validated and the overall power consumption is measured to be 27mW. The entire wearable solution with the battery weight 9.2 grams.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.011
Threshold uncertainty score0.037

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.001
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0110.006

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.020
GPT teacher head0.283
Teacher spread0.263 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2019
Admission routes1
Has abstractyes

Explore more

Same topicEEG and Brain-Computer InterfacesFrench-language works237,207