Laboratory diagnosis of heparin‐induced thrombocytopenia

2019· review· en· W2944052744 on OpenAlexaff
Theodore E. Warkentin

Bibliographic record

VenueInternational Journal of Laboratory Hematology · 2019
Typereview
Languageen
FieldMedicine
TopicHeparin-Induced Thrombocytopenia and Thrombosis
Canadian institutionsMcMaster UniversityHamilton Regional Laboratory Medicine ProgramHamilton Health SciencesHamilton General Hospital
Fundersnot available
KeywordsHeparin-induced thrombocytopeniaHeparinFondaparinuxPlatelet factor 4AntibodyImmunoassayMedicinePlateletImmunologyPlatelet activationInternal medicineThrombosis

Abstract

fetched live from OpenAlex

Heparin-induced thrombocytopenia (HIT) is a clinical-pathological disorder; thus, laboratory testing for the pathogenic platelet-activating antiplatelet factor 4 (PF4)/heparin antibodies is central for diagnosis. The "iceberg" model summarizes the inter-relationship between platelet activation assays and PF4-dependent immunoassays, with platelet-activating antibodies comprising a subset of anti-PF4/heparin antibodies. The platelet serotonin-release assay (SRA), performed by reference laboratories, has high sensitivity and specificity for HIT (~95% each), and is especially suited for detecting highly pathogenic HIT sera containing both heparin-dependent and heparin-independent platelet-activating antibodies; this latter subgroup of antibodies explains "autoimmune HIT" disorders (delayed-onset, persisting, spontaneous, heparin "flush," fondaparinux-associated). Recently, SRA-negative HIT has become recognized, in which serum from some HIT patients contains subthreshold levels of platelet-activating antibodies (by SRA) that become detectable using a PF4-enhanced platelet activation assay. Unusual immunologic features of HIT include early antibody detectability (at onset of platelet count fall) and antibody transience (seroreversion). Widely available PF4-dependent enzyme immunoassays (EIAs) have high sensitivity but poor specificity for HIT, although specificity is enhanced with IgG-specific EIAs and strong positive results; unfortunately, EIA results are usually not available in real time. Automated rapid immunoassays, such as the chemiluminescence immunoassay (CLIA) and latex immunoturbidimetric assay (LIA), facilitate real-time laboratory diagnosis. Recently available likelihood ratio (LR) data for positive (LR+) and negative (LR-) test results allow clinicians to adjust their pretest probabilities for HIT, using Bayesian analysis, into real-time posttest probabilities that are dramatically increased (test positive) or decreased (test negative). Moreover, (semi-)quantitative CLIA- and LIA-positive results (weak, moderate, strong positive) can further refine the posttest probability of HIT.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.920
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0070.001
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.090
GPT teacher head0.406
Teacher spread0.317 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designNot applicable
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations117
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueInternational Journal of Laboratory HematologySame topicHeparin-Induced Thrombocytopenia and ThrombosisFrench-language works237,207