MétaCan
Menu
Back to cohort
Record W2944106437 · doi:10.1101/632125

<i>Shake-it-off</i> : A simple ultrasonic cryo-EM specimen preparation device

2019· preprint· en· W2944106437 on OpenAlexafffund
John L. Rubinstein, Hui Guo, Zev A. Ripstein, Ali Haydaroğlu, Aaron Au, Christopher M. Yip, Justin M. Di Trani, Samir Benlekbir, Timothy Kwok

Bibliographic record

VenuebioRxiv (Cold Spring Harbor Laboratory) · 2019
Typepreprint
Languageen
FieldBiochemistry, Genetics and Molecular Biology
TopicAdvanced Electron Microscopy Techniques and Applications
Canadian institutionsHospital for Sick ChildrenUniversity of Toronto
FundersCanadian Institutes of Health ResearchHospital for Sick ChildrenUniversity of TorontoCanada Research Chairs
KeywordsMaterials scienceSample (material)Ultrasonic sensorComputer scienceMicroscopeGridSample preparationCryo-electron microscopyInterface (matter)VitrificationNanotechnologyOpticsAcousticsComposite materialChromatographyChemistry

Abstract

fetched live from OpenAlex

Abstract Although microscopes and image analysis software for electron cryomicroscopy (cryo-EM) have improved dramatically in recent years, specimen preparation methods have lagged behind. Most strategies still rely on blotting microscope grids with paper to produce a thin film of solution suitable for vitrification. This approach loses more than 99.9% of the applied sample and requires several seconds, leading to problematic air-water interface interactions for macromolecules in the resulting thin film of solution and complicating time-resolved studies. Recently developed self-wicking EM grids allow use of small volumes of sample, with nanowires on the grid bars removing excess solution to produce a thin film within tens of milliseconds from sample application to freezing. Here we present a simple cryo-EM specimen preparation device that uses components from an ultrasonic humidifier to transfer protein solution onto a self-wicking EM grid. The device is controlled by a Raspberry Pi single board computer and all components are either widely available or can be manufactured by online services, allowing the device to be constructed in laboratories that specialize in cryo-EM, rather than instrument design. The simple open-source design permits straightforward customization of the instrument for specialized experiments. Synopsis A method is presented for high-speed low-volume cryo-EM specimen preparation with a device constructed from readily available components.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.236
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.281
Teacher spread0.272 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2019
Admission routes2
Has abstractyes

Explore more