Right Anterior Minithoracotomy for Aortic Valve Replacement: A Widely Applicable, Simple, and Stepwise Approach
Bibliographic record
Abstract
OBJECTIVE: A stepwise approach for right anterior minithoracotomy aortic valve replacement (RAT-AVR), without sutureless valves, special instruments, or preoperative imaging, was developed. We report our experience with this widely applicable, simplified approach. METHODS: Patients with a history of previous chest surgery, documented PVD, severe COPD, LVOT size <2.0 cm, and root size <2.8 cm were excluded. Chest CT was not mandatory. The stepwise surgical approach consists of 1) tolerability of single-lung ventilation; 2) 5-cm long incision on third right anterior ICS; 3) small pericardial opening to localize the aortic valve annular plane by digital palpation; 4) shingling of the correct rib to create a box field; 5) optimizing exposure with stay sutures; 6) femoral or central cannulation with right superior pulmonary vein venting and usual antegrade cardioplegia; 7) performing a standard AVR without adjunct instruments; and 8) reconstructing 1 costochondral cartilage. RESULTS: Fifty-five patients were operated. The mean age was 68.5 years (SD 10.4); 29.1% were female. Median STS PROM was 1.18 (0.4 to 6.6). Pump and cross-clamp times were 104.8 minutes (SD 27.9) and 73.2 minutes (SD 22.8), respectively. There was no need for a knot pusher. There was 1 conversion, 1 reopening for bleeding, and 1 pacemaker insertion. No patient had a stroke, MI, or death at 30 days. The median LOS was 6 days (3 to 19). CONCLUSION: RAT-AVR can be applicable and performed safely in a wide range of patients by adopting a simple, stepwise approach with intraoperative assessment, without the need for special imaging, instrumentation, or advanced training.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.001 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.001 | 0.001 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.002 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".