MétaCan
Menu
Back to cohort
Record W2946548094 · doi:10.1111/jce.14001

How to deliver personalized cardiac resynchronization therapy through the precise measurement of the acute hemodynamic response: Insights from the iSpot trial

2019· article· en· W2946548094 on OpenAlexaff
Matthew Shun‐Shin, Alejandra A. Miyazawa, Daniel Keene, Maciej Sterliński, Adam Sokal, Frédéric Van Heuverswyn, Christopher A. Rinaldi, Richard Cornelussen, Berthold Stegemann, Dárrel P. Francis, Zachary I. Whinnett

Bibliographic record

VenueJournal of Cardiovascular Electrophysiology · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsSt. Thomas Hospital
FundersBritish Heart FoundationNational Institute for Health and Care Research
KeywordsMedicineCardiac resynchronization therapyCardiologyHemodynamicsInternal medicineBlood pressureHeart failureEjection fraction

Abstract

fetched live from OpenAlex

Abstract Introduction New pacing technologies offer a greater choice of left ventricular pacing sites and greater personalization of cardiac resynchronization therapy (CRT). The effects on cardiac function of novel pacing configurations are often compared using multi‐beat averages of acute hemodynamic measurements. In this analysis of the iSpot trial, we explore whether this is sufficient. Materials and Methods The iSpot trial was an international, prospective, acute hemodynamic trial that assessed seven CRT configurations: standard CRT, MultiSpot (posterolateral vein), and MultiVein (anterior and posterior vein) pacing. Invasive and noninvasive blood pressure, and left ventricular (LV) dP/dt max were recorded. Eight beats were recorded before and after an alternation from AAI to the tested pacing configuration and vice‐versa. Eight alternations were performed for each configuration at each of the five atrioventricular delays. Results Twenty‐five patients underwent the full protocol of eight alternations. Only four (16%) patients had a statistically significant >3 mm Hg improvement over conventional CRT configuration (posterolateral vein, distal electrode). However, if only one alternation was analyzed (standard multi‐beat averaging protocol), 15 (60%) patients falsely appeared to have a superior nonconventional configuration. Responses to pacing were significantly correlated between the different hemodynamic measures: invasive systolic blood pressure (SBP) vs noninvasive SBP r = 0.82 ( P < .001); invasive SBP vs LV dP/dt r = 0.57, r 2 = 0.32 ( P < .001). Conclusions Current standard multibeat acquisition protocols are unfortunately unable to prevent false impressions of optimality arising in individual patients. Personalization processes need to include distinct repeated transitions to the tested pacing configuration in addition to averaging multiple beats. The need is not only during research stages but also during clinical implementation.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.741
Threshold uncertainty score0.377

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.245
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations12
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Cardiovascular ElectrophysiologySame topicCardiac pacing and defibrillation studiesFrench-language works237,207