MétaCan
Menu
Back to cohort
Record W2947066970 · doi:10.14814/phy2.14093

Variations in coil temperature/power and e‐liquid constituents change size and lung deposition of particles emitted by an electronic cigarette

2019· article· en· W2947066970 on OpenAlex
Ariane Lechasseur, Simon Altmejd, Natalie Turgeon, Giorgio Buonanno, Lídia Morawska, David Brunet, Caroline Duchaine, Mathieu C. Morissette

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenuePhysiological Reports · 2019
Typearticle
Languageen
FieldMedicine
TopicSmoking Behavior and Cessation
Canadian institutionsUniversité Laval
Fundersnot available
KeywordsElectronic cigaretteParticle sizeDeposition (geology)ChemistryParticle (ecology)Particle depositionPolyvinyl alcoholUltrafine particleParticle-size distributionMaterials scienceGlycerolAnalytical Chemistry (journal)Chemical engineeringChromatographyNanotechnologyRange (aeronautics)Organic chemistryComposite materialPhysical chemistry

Abstract

fetched live from OpenAlex

Electronic cigarette uses propylene glycol and glycerol to deliver nicotine and flavors to the lungs. Given the hundreds of different brands, the thousands of flavors available and the variations in nicotine concentrations, it is likely that electronic cigarette settings and e-liquid composition affect the size distribution of particles emitted and ultimately pulmonary deposition. We used the inExpose e-cigarette extension to study two separate modes of operation of electronic cigarettes, namely power-controlled and the temperature-controlled. We also assessed several e-liquids based on propylene glycol and glycerol concentrations, nicotine content, and selected monomolecular flavoring agents (menthol, vanillin, and maltol). Particle size distribution was measured using a Condensation Particle Counter and a Scanning Mobility Particle Sizer spectrometer. Lung deposition was predicted using the International Commission on Radiological Protection model. For all resistance coils, increase in power delivery generated larger particles while maintaining a higher coil temperature generated smaller particles. Increase in glycerol concentration led to the generation of larger particles. With regard to flavors, we showed that despite minor effect of menthol and maltol, vanillin dramatically increased particle size. Presence of nicotine also increased particle size. Finally, particles emitted by the electronic cigarette were predicted to mainly deposit in the alveoli and conditions generating larger particle sizes led to a reduction in predicted lung deposition. This study shows that coil temperature, propylene glycol and glycerol concentrations, presence of nicotine, and flavors affect the size of particles emitted by an electronic cigarette, directly affecting predicted lung deposition of these particles.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.627
Threshold uncertainty score0.264

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.282
Teacher spread0.267 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it