MétaCan
Menu
Back to cohort
Record W2947907697 · doi:10.1111/aor.13503

Donkey pericardium compares favorably with commercial xenopericardia used in the manufacture of transcatheter heart valves

2019· article· en· W2947907697 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueArtificial Organs · 2019
Typearticle
Languageen
FieldMedicine
TopicCardiac Valve Diseases and Treatments
Canadian institutionsUniversité Laval
FundersNatural Sciences and Engineering Research Council of CanadaCanadian Institutes of Health ResearchHealth Research
KeywordsPericardiumDonkeyBiomedical engineeringHeart valveAnatomyMedicineMaterials scienceSurgeryBiology

Abstract

fetched live from OpenAlex

Transcatheter aortic valve implantation (TAVI) has gained considerable acceptance in the past decade due to its lower risks than conventional open-heart surgery. However, the deformation and delamination of the leaflets during the crimping procedure have raised questions about the durability and long-term serviceability of the pericardium tissue from which the leaflets are made. The collagen architecture, wall thickness and mechanical properties of donkey pericardium were investigated to assess its suitability as an alternative material for the manufacture of heart valves. Coupons sampled from different locations of donkey pericardium were investigated. Bovine, equine, and porcine pericardium specimens served as controls. The donkey pericardium had a similar surface morphology to that of the control pericardia except for the wavy topology on both the fibrous and serous sides. The average thickness of donkey pericardium (ca. 120 µm) was significantly lower than that from bovine (375 µm) and equine (410 µm), but slightly higher than that from porcine (99 µm) specimens. The interlaced wavy collagen bundles in the pericardium were composed of collagen fibers about 100 nm in diameter. This unique structure ensures that the donkey pericardium has a comparable ultimate tensile strength (UTS) and a much higher failure strain than the commercial pericardia used for the manufacture of heart valves. The donkey pericardium has an organized wavy collagen bundle architecture similar to that of bovine pericardium and has a satisfactory UTS and high failure strain. The thin and strong donkey pericardium might be a good candidate valve leaflet material for TAVI.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.471

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.015
GPT teacher head0.302
Teacher spread0.287 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it