MétaCan
Menu
Back to cohort
Record W2950671804 · doi:10.2196/12845

Design of Improved Intertrochanteric Fracture Treatment (DRIFT) Study: Protocol for Biomechanical Testing and Finite Element Analysis of Stable and Unstable Intertrochanteric Fractures Treated With Intramedullary Nailing or Dynamic Compression Screw

2019· article· en· W2950671804 on OpenAlexvenueno aff
Andreas Panagopoulos, Georgios Kyriakopoulos, G. Anastopoulos, Panagiotis Megas, Stavros K. Kourkoulis

Bibliographic record

VenueJMIR Research Protocols · 2019
Typearticle
Languageen
FieldMedicine
TopicHip and Femur Fractures
Canadian institutionsnot available
Fundersnot available
KeywordsIntramedullary rodFinite element methodDynamic hip screwMedicineReduction (mathematics)ImplantOrthodonticsFemurSurgeryEngineeringStructural engineeringMathematics

Abstract

fetched live from OpenAlex

BACKGROUND: Intertrochanteric hip fractures rank in the top 10 of all impairments worldwide in terms of loss in disability-adjusted years for people aged older than 60 years. The type of surgery is usually carried out with dynamic hip screw (DHS) devices or cephalomedullary nails (CMN). Cut-out of the hip screw is considered the most frequent mechanical failure for all implants with an estimated incidence ranging from 2% to 16.5%; this entails both enhancing our understanding of the prognostic factors of cut-out and improving all aspects of intertrochanteric fracture treatment. OBJECTIVE: The Design of Improved Intertrochanteric Fracture Treatment (DRIFT) study's main objective is to provide intertrochanteric fracture treatment expertise, requirements and specifications, clinical relevance, and validation to improve treatment outcomes by developing a universal algorithm for designing patient- and fracture-oriented treatment. The hypothesis to be tested is that a more valgus reduction angle and implants of higher angles will lead to a more favorable biomechanical environment for fracture healing-that is, higher compressive loads at the fracture site with lower shear loads at the hip screw femoral head interface. A new implant with enhanced biomechanical and technical characteristics will be designed and fabricated; in addition, an integrated design and optimization platform based on computer-aided design tools and topology optimization modules will be developed. METHODS: To test this hypothesis, a biomechanical study comprising experimental loading of synthetic femora (Sawbones Inc) and finite element analysis (FEA) will be conducted. Detailed FEA of existing implants (DHS and CMN) implemented in different clinical cases under walking conditions will be performed to derive the stress and strain fields developed at the implant-bone system and identify critical scenarios that could lead to failure of therapy. These models would be validated against instrumented mechanical tests using strain gages and a digital image correlation process. RESULTS: After testing, geometric drawbacks of existing implants will be fully recognized, and geometric characteristics will be correlated with critical failure scenarios. The last step would be the numeric design, computer-aided design (using FEA codes and design packages), and optimization of the new proposed implant with regard to improved biomechanical surgical technique and enhanced mechanical performance that will reduce the possibility for critical failure scenarios. CONCLUSIONS: The optimization of the biomechanical behavior of the fracture-osteosynthesis model by the application of the ideal reduction angle and implant is expected to have a positive effect to the rate of mechanical failure and, subsequently, the healing rates, morbidity, and mortality in this fragile patient group. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/12845.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.006
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Not applicable · Consensus signal: none
GenreCandidate signal: Protocol · Consensus signal: Protocol
Teacher disagreement score0.021
Threshold uncertainty score0.071

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0060.003
Meta-epidemiology (narrow)0.0020.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.000
Open science0.0020.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0210.003

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.137
GPT teacher head0.496
Teacher spread0.358 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNot applicable
Domainnot available
GenreProtocol

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJMIR Research ProtocolsSame topicHip and Femur FracturesFrench-language works237,207