MétaCan
Menu
Back to cohort
Record W2951870941 · doi:10.1097/icl.0000000000000631

The Impact of Cosmetics on the Physical Dimension and Optical Performance of Contemporary Silicone Hydrogel Contact Lenses

2019· article· en· W2951870941 on OpenAlexaff
Doerte Luensmann, Kevin van Doorn, Christina May, Sruthi Srinivasan, Lyndon Jones

Bibliographic record

VenueEye & Contact Lens Science & Clinical Practice · 2019
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsCosmeticsContact lensLens (geology)Silicone hydrogelSiliconeOphthalmologyMaterials scienceChemistryOpticsMedicineComposite material

Abstract

fetched live from OpenAlex

PURPOSE: Contact lens wearers may inadvertently expose their lenses during the lens insertion and removal process or while wearing their lenses to cosmetic products being used. This study investigated the impact of various cosmetics on the physical dimension and optical properties of three recently marketed monthly replacement silicone hydrogel contact lenses. METHODS: In this in vitro study, three monthly replacement silicone hydrogel lens types including senofilcon C (ACUVUE VITA, Johnson & Johnson), samfilcon A (Bausch+Lomb ULTRA, Bausch+Lomb), and lotrafilcon B+EOBO (polyoxyethylene-polyoxybutylene) (AIR OPTIX plus HydraGlyde, ALCON), were individually coated with cosmetic products followed by a 1-hr soak in phosphate-buffered saline. Cosmetic products included; three hand creams (HC1: Glysomed; HC2: Vaseline Healthy Hand & Nail Conditioning; and HC3: Intense Relieve), three make-up removers (MR1: Lid-Care Towelettes; MR2: Gentle waterproof eye and Lip Makeup Remover; and MR3: Oil-Free Makeup Remover), and three mascaras (MA1: Great Lash-waterproof; MA2a: Wonder'Lash-waterproof, and MA3: Voluminous Original). The contact lens dimensions were determined for diameter, sagittal depth, and base curve, using the Chiltern (Optimec Limited), whereas lens power and optical quality were assessed using the Contest Plus II (Rotlex). Six replicates for each lens/cosmetic combination were used. The impact of cosmetics was tested between lenses and compared with uncoated control lenses. RESULTS: For lens diameter, makeup removers (MR2 & MR3) demonstrated the largest impact, with an increase of up to 0.26 mm (MR2) and 0.35 mm (MR3) for senofilcon C and samfilcon A, respectively (P<0.01 compared to baseline), whereas lotrafilcon B+EOBO showed a decrease of 0.01 mm (P<0.01 between lens types). For sagittal depth, mascara MA1 demonstrated the greatest impact, followed by makeup removers MR2 & MR3. All lenses showed increases in sagittal depth after MA1 exposure (0.16±0.06 mm in lotrafilcon B+EOBO, 0.24±0.22, and 0.26±0.09 mm in samfilcon A and senofilcon C, respectively; P<0.01 for all lenses compared with baseline). For base curve, the makeup removers (MR2 & MR3) caused increases for both senofilcon C (up to 0.36 mm) and samfilcon A (up to 0.35 mm), but lotrafilcon B+EOBO was unaffected. Lens power changes were generally minor (<0.25 D). However, senofilcon C showed a significant change of -1.18±0.65 D (more minus) after MA1 exposure (P<0.001). Image quality was most affected by mascaras, although given that all lens types were adversely affected to similar degrees, none of the lenses performed better or worse after mascara application (P>0.05). The parameters of the different lens types were not significantly affected by the hand creams. CONCLUSION: Makeup removers and mascaras changed the lens parameters to varying degrees, which may affect the fit and overall performance of the lens, whereas no such effect was noted with hand creams. Lotrafilcon B+EOBO was typically less affected compared with senofilcon C or samfilcon A.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.007
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.302
Threshold uncertainty score0.788

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.007
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.047
GPT teacher head0.385
Teacher spread0.339 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueEye & Contact Lens Science & Clinical PracticeSame topicOcular Surface and Contact LensFrench-language works237,207