MétaCan
Menu
Back to cohort
Record W2952429243 · doi:10.1139/cjc-2019-0157

Adjustable column length using a water stationary phase in supercritical fluid chromatography

2019· article· en· W2952429243 on OpenAlexafffundvenue
Matthew T. Saowapon, Kevin B. Thurbide

Bibliographic record

VenueCanadian Journal of Chemistry · 2019
Typearticle
Languageen
FieldChemistry
TopicAnalytical Chemistry and Chromatography
Canadian institutionsUniversity of Calgary
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsChemistryVolumetric flow rateSupercritical fluid chromatographyChromatographyCapillary actionSupercritical fluidColumn (typography)Van Deemter equationTwo-dimensional chromatographyPhase (matter)Chromatography columnAnalytical Chemistry (journal)Pressure gradientTemperature gradientMechanicsStationary phaseGas chromatographyMaterials scienceMeteorology

Abstract

fetched live from OpenAlex

A novel method for adjusting the column length during analysis in capillary supercritical fluid chromatography (SFC) is introduced. The approach is based on using a water stationary phase that can be partially ejected (or replenished) from the column as desired, without physically removing the supporting hardware elements. By flowing cool air through a sleeve surrounding the column in a heated oven, an axial thermal gradient along the length of the column was formed. This established a cooler region where the water stationary phase could be maintained and a hotter region where the coating was removed through dehydration. As such, the effective column length could be easily adjusted by changing the gradient via the air flow rate. Using this prototype arrangement, column lengths could be readily varied between 1.4 and 10 m. System response was also fairly rapid and changes took effect in under 1 min. Once a given length was established, retention times were highly reproducible with a relative standard deviation of 1.8% (n = 3). The method is cheaper and faster than the conventional method of storing numerous columns for manual switching. Further, it avoids the convolution of system pressure and flow rate that accompanies the pressure adjustments normally used to optimize capillary SFC separations. Results indicate that this approach could be a useful alternative for adjusting column length to optimize separation speed and resolution.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0010.001
Scholarly communication0.0010.002
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.233
Teacher spread0.223 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2019
Admission routes3
Has abstractyes

Explore more

Same venueCanadian Journal of ChemistrySame topicAnalytical Chemistry and ChromatographyFrench-language works237,207