MétaCan
Menu
Back to cohort
Record W2952500082 · doi:10.1016/j.jcmg.2019.03.030

Application of Low Tube Potentials in CCTA

2019· article· en· W2952500082 on OpenAlexaff
Thomas J. Stocker, Jonathon Leipsic, Martin Hadamitzky, Marcus Y. Chen, Ronen Rubinshtein, Simon Deseive, Mathias Heckner, Jeroen J. Bax, Kakuya Kitagawa, Hugo Marques, Axel Schmermund, Claudio Silva, John J. Mahmarian, Joon‐Won Kang, Erik Lerkevang Grove, John R. Lesser, Steffen Maßberg, Jörg Hausleiter

Bibliographic record

VenueJACC. Cardiovascular imaging · 2019
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsUniversity of British Columbia
FundersMerck Sharp and DohmeAbbott VascularAbbott LaboratoriesGE HealthcareMedtronicNational Institutes of HealthBoston Scientific CorporationBoehringer IngelheimBiotronikBayerBristol-Myers SquibbAstraZenecaPfizer
KeywordsTube (container)Materials scienceComposite material

Abstract

fetched live from OpenAlex

OBJECTIVES: The aim of this study was to assess the use of low tube potentials for coronary computed tomography angiography (CCTA) in worldwide clinical practice and its influence on radiation exposure, contrast agent volume, and image quality. BACKGROUND: CCTA is frequently used in clinical practice. Lowering of tube potential is a potent method to reduce radiation exposure and to economize contrast agent volume. METHODS: CCTAs of 4,006 patients from 61 international study sites were analyzed regarding very-low (≤80 kVp), low (90 to 100 kVp), conventional (110 to 120 kVp), and high (≥130 kVp) tube potentials. The impact on dose-length product (DLP) and contrast agent volume was analyzed. Image quality was determined by evaluation of the diagnostic applicability and assessment of the objective image parameters signal-to-noise-ratio (SNR) and contrast-to-noise-ratio (CNR). RESULTS: When compared with conventional tube potentials, low tube potentials were used in 56% of CCTAs (≤80 kVp: 9%; 90 to 100 kVp: 47%), which varied among sites from 0% to 100%. Tube potential reduction was associated with low-cardiovascular risk profile, low body mass index (BMI), and new-generation scanners. Median radiation exposure was lowered by 68% or 50% and median contrast agent volume by 25% or 13% for tube potential protocols of ≤80 kVp or 90 to 100 kVp when compared with conventional tube potentials, respectively (all p < 0.001). With the use of lower tube potentials, the frequency of diagnostic scans was maintained (p = 0.41), whereas SNR and CNR significantly improved (both p < 0.001). Considering BMI eligibility criteria, 58% (n = 946) of conventionally scanned patients would have been suitable for low tube potential protocols, and 44% (n = 831) of patients scanned with 90 to 100 kVp would have been eligible for very-low tube potential CCTA imaging of ≤80 kVp. CONCLUSIONS: This large international registry confirms the feasibility of tube potential reduction in clinical practice leading to lower radiation exposure and lower contrast volumes. The current registry also demonstrates that this strategy is still underused in daily practice. (PROspective multicenter registry on radiaTion dose Estimates of cardiac CT angIOgraphy iN daily practice in 2017 [PROTECTION-VI]; NCT02996903).

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.335
Threshold uncertainty score0.496

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.223
Teacher spread0.220 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations45
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJACC. Cardiovascular imagingSame topicRadiation Dose and ImagingFrench-language works237,207