Pulse Rate Variability in Emergency Physicians During Shifts: Pilot Cross-Sectional Study
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: The high prevalence of physician burnout, particularly in emergency medicine, has garnered national attention in recent years. Objective means of measuring stress while at work can facilitate research into stress reduction interventions, and wearable photoplethysmography (PPG) technology has been proposed as a potential solution. However, the use of low-burden wearable biosensors to study training and clinical practice among emergency physicians (EP) remains untested. OBJECTIVE: This pilot study aimed to (1) determine the feasibility of recording on-shift photoplethysmographic data from EP, (2) assess the quality of these data, and (3) calculate standard pulse rate variability (PRV) metrics from the acquired dataset and examine patterns in these variables over the course of an academic year. METHODS: A total of 21 EP wore PPG biosensors on their wrists during clinical work in the emergency department during a 9-hour shift. Recordings were collected during the first quarter of the academic year, then again during the fourth quarter of the same year for comparison. The overall rate of usable data collection per time was computed. Standard pulse rate (PR) and PRV metrics from these two time points were calculated and entered into Student t tests. RESULTS: More than 400 hours of data were entered into these analyses. Interpretable data were captured during 8.54% of the total recording time overall. In the fourth quarter of the academic year compared with the first quarter, there was no significant difference in median PR (75.8 vs 76.8; P=.57), mean R-R interval (0.81 vs 0.80; P=.32), SD of R-R interval (0.11 vs 0.11; P=.93), root mean square of successive difference of R-R interval (0.81 vs 0.80; P=.96), low-frequency power (3.5×103 vs 3.4×103; P=.79), high-frequency power (8.5×103 vs 8.3×103; P=.91), or low-frequency to high-frequency ratio (0.42 vs 0.41; P=.43), respectively. Power estimates for each of these tests exceeded .90. A secondary analysis of the resident-only subgroup similarly showed no significant differences over time, despite power estimates greater than .80. CONCLUSIONS: Although the use of PPG biosensors to record real-time physiological data from EP while providing clinical care seems operationally feasible, this study fails to support the notion that such an approach can efficiently provide reliable estimates of metrics of interest. No significant differences in PR or PRV metrics were found at the end of the year compared with the beginning. Although these methods may offer useful applications to other domains, it may currently have limited utility in the contexts of physician training and wellness.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it