MétaCan
Menu
Back to cohort
Record W2963136959 · doi:10.1097/opx.0000000000001410

A 3‐year Randomized Clinical Trial of MiSight Lenses for Myopia Control

2019· article· en· W2963136959 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueOptometry and Vision Science · 2019
Typearticle
Languageen
FieldMedicine
TopicOphthalmology and Visual Impairment Studies
Canadian institutionsUniversity of Waterloo
FundersUniversidade do MinhoUniversity of WaterlooNational University Health SystemNationale Genossenschaft für die Lagerung radioaktiver AbfälleAston UniversityCooperVision
KeywordsMedicineRandomized controlled trialContact lensAstigmatismOphthalmologyRefractionAdverse effectClinical trialOptometrySurgeryInternal medicineOptics

Abstract

fetched live from OpenAlex

SIGNIFICANCE: Results of this randomized, double-masked clinical trial demonstrate the effectiveness of the MiSight soft contact lens in slowing myopia progression over multiple years. PURPOSE: The purpose of this study was to quantify the effectiveness of MiSight daily disposable soft contact lens in slowing the progression of juvenile-onset myopia. METHODS: Myopic children (spherical equivalent refraction, -0.75 to -4.00 D; astigmatism, <1.00 D) aged 8 to 12 years with no prior contact lens experience were enrolled in a 3-year, double-masked, randomized clinical trial at four investigational sites in four countries. Subjects in each group were matched for age, sex, and ethnicity and were randomized to either a MiSight 1-day contact lens (test) or Proclear 1-day (control; omafilcon A) and worn on a daily disposable basis. Primary outcome measures were the change in cycloplegic spherical equivalent refraction and axial length. RESULTS: Of the subjects enrolled, 75.5% (109/144) completed the clinical trial (53 test, 56 control). Unadjusted change in spherical equivalent refraction was -0.73 D (59%) less in the test group than in the control group (-0.51 ± 0.64 vs. -1.24 ± 0.61 D, P < .001). Mean change in axial length was 0.32 mm (52%) less in the test group than in the control group (0.30 ± 0.27 vs. 0.62 ± 0.30 mm, P < .001). Changes in spherical equivalent refraction and axial length were highly correlated (r = -0.90, P < .001). Over the course of the study, there were no cases of serious ocular adverse events reported. Four asymptomatic corneal infiltrative (one test, three control) events were observed at scheduled study visits. CONCLUSIONS: Results of this clinical trial demonstrate the effectiveness of the MiSight daily disposable soft contact lens in slowing change in spherical equivalent refraction and axial length.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.005
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.054
Threshold uncertainty score0.412

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0050.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.048
GPT teacher head0.533
Teacher spread0.485 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it