MétaCan
Menu
Back to cohort
Record W2963358755 · doi:10.1177/1129729819863556

Should the CDC’s recommendations for promptly removing unnecessary centrally inserted central catheters be enhanced? Ultrasound-guided peripheral venous cannulation to fully comply

2019· article· en· W2963358755 on OpenAlexaff
Stelios Iordanou, Nicos Middleton, Elisavet Papathanassoglou, Lakis Palazis, Vasilios Raftopoulos

Bibliographic record

VenueThe Journal of Vascular Access · 2019
Typearticle
Languageen
FieldHealth Professions
TopicCentral Venous Catheters and Hemodialysis
Canadian institutionsUniversity of Alberta
Fundersnot available
KeywordsMedicineCatheterCentral lineBloodstream infectionPeripheralIncidence (geometry)Central venous catheterSurgeryInfection controlIntensive care unitUltrasoundIntensive care medicineRadiologyInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: In an effort to reduce catheter-related bloodstream infection's incidence rates in an intensive care unit, several evidence-based procedures recommended by the Centers for Disease Control and Prevention for centrally inserted central catheters were implemented. A failure to fully comply with the recommendation for prompt removal of the centrally inserted central catheters was attributed, mainly to the difficulties and inadequacies raised from establishing peripheral venous access. METHODS: The ultrasound-guided peripheral venous cannulation method as a supplementary intervention to the Centers for Disease Control and Prevention's recommendations was incorporated and examined during the subsequent year. RESULTS: A significant reduction on catheter-related bloodstream infection incidence rates out of the expected range was found. Centrally inserted central catheters utilization ratios were reduced by 10.7% (p < 0.05; 58%-47%) and the catheter-related bloodstream infection incidence rate was reduced by 11.7 per thousand device-days (15.9-4.16/1000 centrally inserted central catheters days (2015-2016 group, respectively)). CONCLUSION: The reduction of catheter-related bloodstream infection was higher than that described in the published literature. This probably shows that the combination of the five evidence-based procedures recommended by the Centers for Disease Control and Prevention together with that of ultrasound-guided peripheral venous cannulation method can increase the compliance with the Category IA recommendation for removal or avoidance of unnecessary placement of centrally inserted central catheters and decrease the catheter-related bloodstream infections in a more effective way, by affecting the patients' centrally inserted central catheter exposure.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.023
metaresearch head score (Gemma)0.104
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.023
Threshold uncertainty score0.124

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0230.104
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0030.001
Open science0.0020.001
Research integrity0.0030.004
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.091
GPT teacher head0.396
Teacher spread0.304 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueThe Journal of Vascular AccessSame topicCentral Venous Catheters and HemodialysisFrench-language works237,207