MétaCan
Menu
← Back to cohort
Record W2967879763

Usability study of a device for compensation of foot drop based on FES and surface multi-field electrodes in a clinical environment

2017· article· en· W2967879763 on OpenAlexaboutno aff
Eukene Imatz-Ojanguren, Gema Sánchez-Márquez, Jose Ramón Asiain-Aristu, Joxean Cueto-Mendo, Edurne Jaunarena-Goicoechea, Haritz Zabaleta, Thierry Keller

Bibliographic record

VenueTECNALIA Publications (Fundación TECNALIA Research & Innovation) · 2017
Typearticle
Languageen
FieldEngineering
TopicAdvanced Sensor and Energy Harvesting Materials
Canadian institutionsnot available
Fundersnot available
KeywordsUsabilityFoot dropFoot (prosody)Compensation (psychology)Drop (telecommunication)ElectrodeComputer sciencePhysical medicine and rehabilitationHuman–computer interactionEngineeringElectrical engineeringMedicinePsychologyChemistrySocial psychology
DOInot available

Abstract

fetched live from OpenAlex

Functional Electrical Stimulation (FES) has shown successful assistive and rehabilitation effects in people affected by foot drop dysfunction caused by neurological disorders [1]. Still, FES-based foot drop devices are not present in regular therapy programs of many countries due to barriers caused by technological, usability or reliability issues [2]. FES devices based on surface multi-field electrodes bring new broader stimulation possibilities and features like compensation of eversion/inversion and thus, potentially increase the configuration options. In this study, the satisfaction and usability aspects of a multi-field based FES device were analyzed in a clinical environment. Method The FES device used in this study was the Fesia Walk device for compensation of foot drop, which is based on a multi-field surface electrode and an inertial sensor for gait phase detection. 10 acquired brain injury subjects in chronic stage and 4 therapists participated in the study. The therapists received a two-hour training session prior to the therapy sessions. Every subject was assigned to one therapist and received 3 sessions of habituation and 6 sessions of over ground walking with the Fesia Walk during three weeks. Both therapists and users were evaluated with the Quebec User Evaluation of Satisfaction with Assistive Technology (QUEST). Additionally, the therapists were evaluated with the System Usability Scale (SUS). An individual interview was carried out with each of the participants. Results The device received good scores in both the QUEST and SUS scales, with mean scores of 4.14 out of 5 and 85.6 out of 100 respectively. Furthermore, most users and all therapists showed interest to continue using the device after the study. Discussion and conclusions This usability study indicated that it is possible to include surface multi-field based FES devices for the compensation of foot drop in practical therapeutic programs and that they can be used as regular tools by therapists in clinical environments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.007
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.007
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.204
GPT teacher head0.443
Teacher spread0.239 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations0
Published2017
Admission routes1
Has abstractyes

Explore more

Same venueTECNALIA Publications (Fundación TECNALIA Research & Innovation)→Same topicAdvanced Sensor and Energy Harvesting Materials→French-language works237,207→