MétaCan
Menu
Back to cohort
Record W2969810106 · doi:10.1109/tbme.2019.2936972

Enhanced Detection of Bubble Emissions Through the Intact Spine for Monitoring Ultrasound-Mediated Blood-Spinal Cord Barrier Opening

2019· article· en· W2969810106 on OpenAlexafffund
Stecia‐Marie Fletcher, Natalia Ogrodnik, Meaghan A. O’Reilly

Bibliographic record

VenueIEEE Transactions on Biomedical Engineering · 2019
Typearticle
Languageen
FieldEngineering
TopicUltrasound and Hyperthermia Applications
Canadian institutionsUniversity of TorontoSunnybrook Health Science Centre
FundersNational Institute of Biomedical Imaging and BioengineeringOntario Ministry of Research, Innovation and ScienceCanada Research ChairsLantheus Medical Imaging
KeywordsSpinal cordUltrasoundBiomedical engineeringAcousticsMedicineNeuroscienceRadiologyPhysicsPsychology

Abstract

fetched live from OpenAlex

Objective: We previously developed short burst, phase keying (SBPK) focused ultrasound (FUS) to mitigate standing waves in the human vertebral canal. Here, we show microbubble emissions from these pulses can be detected through the human vertebral arch and that these pulses are effective for blood-spinal cord barrier (BSCB) opening. Methods: At f0= 514 kHz, circulating microbubbles were sonicated through ex vivo human vertebrae (60 kPa-1 MPa) using a dual-aperture approach and SBPK exposures engineered to incorporate pulse inversion (PI). Signals from a 250 kHz receiver were analyzed using PI, short-time Fourier analysis and the maximum projection over the pulse train. In rats (n = 14), SBPK FUS+microbubbles was applied to 3 locations/spinal cord at fixed pressures (~0.20-0.47 MPa). MRI and histology were used to assess opening and tissue damage. Results: In human vertebrae between 0.2-0.4 MPa, PI amplified the microbubble/baseline ratio at f0/2 and 2f0by 202 ± 40% (132-291%). This was maximal at 0.4 MPa, coinciding with the onset of broadband emissions. In vivo, opening was achieved at 40/42 locations, with mean MRI enhancement of 46 ± 32%(16%-178%). Using PI, f0/2 was detected at 14/40 opening locations. At the highest pressures (f0/2 present) histology showed widespread bleeding throughout the focal region. At the lowest pressures, opening was achieved without bleeding. Conclusion: This study confirmed that PI can increase sensitivity to transvertebral detection of microbubble signals. Preliminary in vivo investigations show that SBPK FUS can increase BSCB permeability without tissue damage. Significance: SBPK is a clinically relevant pulse scheme and, in combination with PI, provides a means of mediating and monitoring BSCB opening noninvasively.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.240
Teacher spread0.230 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations19
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueIEEE Transactions on Biomedical EngineeringSame topicUltrasound and Hyperthermia ApplicationsFrench-language works237,207