MétaCan
Menu
Back to cohort
Record W2970058991 · doi:10.1117/12.2528965

Fundus camera versus smartphone camera attachment: image quality analysis

2019· article· en· W2970058991 on OpenAlexaff
Nicole Barritt, Mohana Kuppuswamy Parthasarathy, Ibrahim Faruq, John Zelek, Vasudevan Lakshminarayanan

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMedicine
TopicRetinal Imaging and Analysis
Canadian institutionsExfo Electro-Optical Engineering (Canada)University of Waterloo
Fundersnot available
KeywordsFundus cameraArtificial intelligenceFundus (uterus)Computer visionImage qualityComputer scienceOptometryMedicineOphthalmologyImage (mathematics)RetinalOphthalmoscopy

Abstract

fetched live from OpenAlex

Fundus cameras are the current clinical standard for capturing retinal images, which are used to diagnose a variety of sight-threatening conditions. Traditional fundus cameras are not easily transported, making them unsuitable for field use. In addition, traditional fundus cameras are expensive. Due to this, a variety of technologies have been developed such as the D-EYE Digital Ophthalmoscope (D-EYE Srl, Padova, Italy) which is compatible with various cellphone cameras. This paper reports on the comparison of the image quality of the Nidek RS-330 OCT Retina Scan Duo (Nidek, Tokyo, Japan) and the D-EYE paired with an iPhone 6 (Apple, Cupertino, USA). Twenty-one participants were enrolled in the study of whom 14 underwent nonmydriatic and mydriatic imaging with the D-EYE and the Nidek. Seven participants underwent nonmydriatic imaging with the D-EYE and the Nidek. The images were co-registered and cropped so that the region of interest was equal in both the D-EYE and Nidek images, as the D-EYE had a smaller field of view. Using the Nidek image as the reference, objective full-reference image quality analysis was performed. Metrics such as structural similarity index and peak signal noise ratio were obtained. It was found that the image quality of the D-EYE is limited by the attached iPhone camera, and is lower when compared to the Nidek. Quantification of the differences between the D-EYE and Nidek allows for targeted development of smartphone camera attachments that can help to bridge the current gap in image quality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.021

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.002
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.001
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.030
GPT teacher head0.363
Teacher spread0.333 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2019
Admission routes1
Has abstractyes

Explore more

Same topicRetinal Imaging and AnalysisFrench-language works237,207