Optical design of a 2× zoom lens for miniature imaging systems
Bibliographic record
Abstract
The optical design of a compact 2 × zoom lens in a lens barrel for miniature cameras is reported. The magnification in the optical system is achieved by means of changing positions of lens elements inside the lens barrel. Six lens elements are employed in the optical system, where up to four elements are actuated. Maximum travel distances for the moving parts are determined as 1.67 mm to reach a magnification of 2.06 × , and the total track length for the telephoto zoom lens state is 9.16 mm at its most extended configuration. Manufacturability of the proposed system is also discussed using a tolerance analysis. The designed optical system is suitable for use with image sensors up to 13 MP, and it can be employed in an endoscopic camera, where the optical zoom and compact design are beneficial. It is also suitable for smartphone cameras with further enhancements and integration of voice-coil-motors and/or MEMS actuators.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.001 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.000 |
| Insufficient payload (model declined to judge) | 0.003 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".