MétaCan
Menu
Back to cohort
Record W2970393872 · doi:10.1063/1.5112760

Characterization and applications of auto-locked vacuum-sealed diode lasers for precision metrology

2019· article· en· W2970393872 on OpenAlexafffund
H. C. Beica, Alexander Pouliot, A. Carew, A. Vorozcovs, N. Afkhami-Jeddi, Thomas Vacheresse, Gehrig Carlse, P. Dowling, Boris Barron, A. Kumarakrishnan

Bibliographic record

VenueReview of Scientific Instruments · 2019
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Fiber Laser Technologies
Canadian institutionsYork University
FundersNatural Sciences and Engineering Research Council of CanadaCanada Foundation for InnovationYork UniversityOntario Centres of ExcellenceOntario Innovation Trust
KeywordsLaserGravimeterMetrologyOpticsAllan varianceNoise floorMaterials scienceLaser linewidthTunable laserDiodePhysicsOptoelectronicsInterferometryAcousticsStandard deviationNoise measurementNoise reduction

Abstract

fetched live from OpenAlex

We demonstrate the performance characteristics of a new class of vacuum-sealed, autolocking diode laser systems and their applications to precision metrology. The laser is based on adaptations of a design that uses optical feedback from an interference filter and it includes a vacuum-sealed cavity, an interchangeable base-plate, and an autolocking digital controller. A change of the base-plate allows operation at desired wavelengths in the visible and near infrared spectral range, whereas the autolocking ability allows the laser to be tuned and frequency stabilized with respect to atomic, molecular, and solid-state resonances without human intervention using a variety of control algorithms programmed into the same controller. We characterize the frequency stability of this laser system based on the Allan deviation (ADEV) of the beat note and of the lock signal. We find that the ADEV floor of 2 × 10−12 and short-term linewidth of ∼200 kHz are strongly influenced by current noise and vacuum sealing. Reducing the current noise and cavity pressure decreases the ADEV floor and increases the averaging time at which the floor occurs, which is a signature of long-term stability. We also show that evacuating the cavity to ∼1 Torr reduces the range of the correction signal of the feedback loop by approximately one order of magnitude, thereby increasing the lock range of the controller. The long-term stability allows the laser to be incorporated into a commercial gravimeter for accurate measurements of gravitational acceleration at the level of a few parts-per-billion, which are comparable to values obtained with an iodine-stabilized He–Ne laser. The autolocking and pattern-matching features of the controller allow the laser to be tuned and stabilized with respect to a temperature tunable transmission spectrum of a fiber-Bragg grating. This capability may be suitable for the development of a differential absorption LIDAR transmitter that can generate data at both on-line and off-line lock points using a single laser.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.825
Threshold uncertainty score0.322

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.268
Teacher spread0.258 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueReview of Scientific InstrumentsSame topicAdvanced Fiber Laser TechnologiesFrench-language works237,207