MétaCan
Menu
Back to cohort
Record W2971351078 · doi:10.1002/rth2.12251

Post‐thrombotic syndrome in children: Measurement properties of CAPTSure, a new diagnostic tool

2019· article· en· W2971351078 on OpenAlexafffund
Laura Avila, Brian M. Feldman, Eleanor Pullenayegum, Celeste Lumia, Madeline I. Montoya, Jennifer Vincelli, Suzan Williams, Leonardo R. Brandão

Bibliographic record

VenueResearch and Practice in Thrombosis and Haemostasis · 2019
Typearticle
Languageen
FieldMedicine
TopicBlood Coagulation and Thrombosis Mechanisms
Canadian institutionsPublic Health OntarioUniversity of TorontoInstitute for Clinical Evaluative SciencesSickKids FoundationHospital for Sick Children
FundersCanadian Institutes of Health Research
KeywordsPost-thrombotic syndromeMedicineInternal medicineThrombosisVenous thrombosis

Abstract

fetched live from OpenAlex

BACKGROUND: CAPTsure (Clinical Assessment of PTS) is a new tool for diagnosis and severity rating of pediatric postthrombotic syndrome (PTS). Our objective was to test the reliability, measurement error, and minimal detectable change of CAPTSure. METHODS: Children aged newborn to 18 years who sustained upper extremity or lower extremity deep vein thrombosis (DVT) were enrolled ≥ 6 months after DVT diagnosis. Patients were assessed by 2 raters to determine the reliability of the clinician assessment component (CC) of CAPTSure. Patients/proxies completed CAPTSure at baseline and approximately 2 weeks later to assess test-retest reliability of the symptoms component (SC). RESULTS: Of 148 patients enrolled in the study; 30 had sustained either bilateral or both upper and lower extremity DVT. Hence, 178 extremities were assessed for PTS signs (86 upper extremity, 92 lower extremity). Intraclass correlation coefficient (ICC) for the CC was 0.89 (95% confidence interval [CI], 0.84-0.93) for upper extremity and 0.88 (95% CI, 0.83-0.92) for lower extremity. Nonclinicians performed 59% of measurements. Ninety-eight patients completed the SC at baseline and follow-up, for a total of 60 upper extremity and 61 lower extremity assessments. ICC for the SC was 0.89 (95% CI, 0.84-0.93) for upper extremity and 0.92 (0.87-0.95) for lower extremity. ICC for CAPTSure was 0.92 (95% CI, 0.87-0.95) for upper extremity and 0.93 (95% CI, 0.88-0.95) for lower extremity assessment. Measurement error ranged between 1.7 and 4.3 of 100 points. A change of approximately 11 of 100 points in CAPTSure score would be required to be confident that there was a change in PTS severity. CONCLUSION: CAPTSure has excellent reliability and a small measurement error, even when applied by nonhematologists.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.011
metaresearch head score (Gemma)0.038
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.011
Threshold uncertainty score0.058

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0110.038
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.001
Science and technology studies0.0000.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.208
GPT teacher head0.374
Teacher spread0.166 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueResearch and Practice in Thrombosis and HaemostasisSame topicBlood Coagulation and Thrombosis MechanismsFrench-language works237,207