MétaCan
Menu
Back to cohort
Record W2973683106 · doi:10.1002/mrm.28232

High‐fidelity, accelerated whole‐brain submillimeter in vivo diffusion MRI using gSlider‐spherical ridgelets (gSlider‐SR)

2020· preprint· en· W2973683106 on OpenAlexaff
Gabriel Ramos‐Llordén, Lipeng Ning, Congyu Liao, Rinat Mukhometzianov, Oleg Michailovich, Kawin Setsompop, Yogesh Rathi

Bibliographic record

VenueMagnetic Resonance in Medicine · 2020
Typepreprint
Languageen
FieldMedicine
TopicAdvanced Neuroimaging Techniques and Applications
Canadian institutionsUniversity of Waterloo
FundersNational Institute of Mental Health
KeywordsScannerComputer scienceDiffusion MRIRedundancy (engineering)Human Connectome ProjectNoise (video)Data acquisitionAngular resolution (graph drawing)Image resolutionSignal-to-noise ratio (imaging)Monte Carlo methodSIGNAL (programming language)Artificial intelligenceComputer visionPhysicsMagnetic resonance imagingMathematics

Abstract

fetched live from OpenAlex

Purpose To develop an accelerated, robust, and accurate diffusion MRI acquisition and reconstruction technique for submillimeter whole human brain in vivo scan on a clinical scanner. Methods We extend the ultra‐high resolution diffusion MRI acquisition technique, gSlider, by allowing undersampling in q‐space and radiofrequency (RF)‐encoding space, thereby dramatically reducing the total acquisition time of conventional gSlider. The novel method, termed gSlider‐SR, compensates for the lack of acquired information by exploiting redundancy in the dMRI data using a basis of spherical ridgelets (SR), while simultaneously enhancing the signal‐to‐noise ratio. Using Monte Carlo simulation with realistic noise levels and several acquisitions of in vivo human brain dMRI data (acquired on a Siemens Prisma 3T scanner), we demonstrate the efficacy of our method using several quantitative metrics. Results For high‐resolution dMRI data with realistic noise levels (synthetically added), we show that gSlider‐SR can reconstruct high‐quality dMRI data at different acceleration factors preserving both signal and angular information. With in vivo data, we demonstrate that gSlider‐SR can accurately reconstruct 860 μm diffusion MRI data (64 diffusion directions at ), at comparable quality as that obtained with conventional gSlider with four averages, thereby providing an eight‐fold reduction in scan time (from 1 hour 20 to 10 minutes). Conclusions gSlider‐SR enables whole‐brain high angular resolution dMRI at a submillimeter spatial resolution with a dramatically reduced acquisition time, making it feasible to use the proposed scheme on existing clinical scanners.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: Methods
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.108
GPT teacher head0.374
Teacher spread0.266 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAdvanced Neuroimaging Techniques and ApplicationsFrench-language works237,207