Abstract

fetched live from OpenAlex

The aim of this project was to investigate the effects of different types of graft material, and different remaining segments of the native TM on its motion. In twelve human temporal bones, controlled TM perforations were made to simulate three different conditions. (1) Central perforation leaving both annular and umbo rims of native TM. (2) Central perforation leaving only a malleal rim of native TM. (3) Central perforation leaving only an annular rim of native TM. Five different graft materials (1) perichondrium (2) silastic (3) thin cartilage (4) thick cartilage (5) Lotriderm® cream were used to reconstruct each perforation condition. Umbo and stapes vibrations to acoustic stimuli from 250 to 6349 Hz were measured using a scanning laser Doppler vibrometer. Results showed that at low frequencies: in the Two Rims condition, all grafting materials except thick cartilage and Lotriderm cream showed no significant difference in umbo velocity from the Normal TM, while only Lotriderm cream showed a significant decrease in stapes velocity; in the Malleal Rim condition, all materials showed a significant decrease in both umbo and stapes velocities; in the Annular Rim condition, all grafting materials except Lotriderm and perichondrium showed no significant difference from the Normal TM in stapes velocity. Umbo data might not be reliable in some conditions because of coverage by the graft. At middle and high frequencies: all materials showed a significant difference from the Normal TM in both umbo and stapes velocities for all perforation conditions except in the Annular Rim condition, in which silastic and perichondrium showed no significant difference from the Normal TM at umbo velocity in the middle frequencies. In the low frequencies, the choice of repair material does not seem to have a large effect on sound transfer. Our data also suggests that the annular rim could be important for low frequency sound transfer.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.032
GPT teacher head0.231
Teacher spread0.199 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2019
Admission routes2
Has abstractyes

Explore more

Same venuePLoS ONESame topicEar Surgery and Otitis MediaFrench-language works237,207