MétaCan
Menu
Back to cohort
Record W2977066285 · doi:10.1002/mrm.27999

Hyperpolarized <sup>129</sup>Xe imaging of embryonic stem cell‐derived alveolar‐like macrophages in rat lungs: proof‐of‐concept study using superparamagnetic iron oxide nanoparticles

2019· article· en· W2977066285 on OpenAlexafffund
Vlora Riberdy, Michael L. Litvack, Elaine Stirrat, Marcus J. Couch, Martin Post, Giles Santyr

Bibliographic record

VenueMagnetic Resonance in Medicine · 2019
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAtomic and Subatomic Physics Research
Canadian institutionsHospital for Sick ChildrenUniversity of Toronto
FundersNatural Sciences and Engineering Research Council of CanadaOntario Institute for Regenerative MedicineHospital for Sick Children
KeywordsHistologyLungIn vivoChemistryNuclear medicineMagnetic resonance imagingPathologyMedicineBiologyInternal medicineRadiology

Abstract

fetched live from OpenAlex

Purpose To measure regional changes in hyperpolarized 129Xe MRI signal and apparent transverse relaxation ( ) because of instillation of SPION‐labeled alveolar‐like macrophages (ALMs) in the lungs of rats and compare to histology. Methods MRI was performed in 6 healthy mechanically ventilated rats before instillation, as well as 5 min and 1 h after instillation of 4 million SPION‐labeled ALMs into either the left or right lung. maps were calculated from 2D multi‐echo data at each time point and changes in were measured and compared to control rats receiving 4 million unlabeled ALMs. Histology of the ex vivo lungs was used to compare the regional MRI findings with the locations of the SPION‐labeled ALMs. Results Regions of signal loss were observed immediately after instillation of unlabeled and SPION‐labeled ALMs and persisted at least 1 h in the case of the SPION‐labeled ALMs. This was reflected in the measurements of . One hour after the instillation of SPION‐labeled ALMs, the decreased to 54.0 ± 7.0% of the baseline, compared to a full recovery to baseline after the instillation of unlabeled ALMs. Histology confirmed the co‐localization of SPION‐labeled ALMs with regions of signal loss and decreases for each rat. Conclusion Hyperpolarized 129Xe MRI can detect the presence of SPION‐labeled ALMs in the airways 1 h after instillation. This approach is promising for targeting and tracking of stem cells for the treatment of lung disease.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.002

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.268
Teacher spread0.255 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueMagnetic Resonance in MedicineSame topicAtomic and Subatomic Physics ResearchFrench-language works237,207