MétaCan
Menu
Back to cohort
Record W2977066615 · doi:10.1039/c9nr05386g

Towards label-free, wash-free and quantitative B-type natriuretic peptide detection for heart failure diagnosis

2019· article· en· W2977066615 on OpenAlexafffund
Zhi Li, Irfani R. Ausri, Yael Zilberman, Xiaowu Tang

Bibliographic record

VenueNanoscale · 2019
Typearticle
Languageen
FieldEngineering
TopicElectrochemical sensors and biosensors
Canadian institutionsUniversity of Waterloo
FundersUniversity of WaterlooNatural Sciences and Engineering Research Council of CanadaMitacs
KeywordsNatriuretic peptideHeart failurePeptideMaterials scienceInternal medicineMedicineCardiologyChemistryBiochemistry

Abstract

fetched live from OpenAlex

Current diagnostic systems used in clinical settings to detect protein biomarkers require highly trained experts, large volumes of blood samples, and long turnaround times. There is an immense need for a low-cost and accurate point-of-care-testing (POCT) device for home monitoring of protein biomarkers for global pandemics such as heart failure (HF). The integration of highly sensitive carbon nanotube (CNT) thin film (CNT-TF) impedance sensors with the electrochemical impedance spectroscopy (EIS) technique is a promising platform to actualize POCT systems for home use. Herein, we report such a system, NanoBot, which allows the label-free and wash-free detection of the HF antigen biomarker B-type natriuretic peptide (BNP) in blood plasma. The NanoBot system consists of two parts: a disposable test strip and a miniature electronic readout unit. The NanoBot exhibited reasonable accuracy and precision, a clinically relevant limit of detection (LOD) as low as 16 pg mL-1, a linear detection range from 0-4000 pg mL-1 and excellent correlation with a reference standard fluorescent immunoassay (FIA). A pilot clinical study with patient-derived blood plasma validated the NanoBot's strong performance compared to that of Alere Triage®, with an interclass correlation coefficient (ICC) of 98% and a square of correlation coefficient (CC) of 0.95. Furthermore, unlike the Alere Triage® that requires more than 250 μL of blood collected via venipuncture, the NanoBot only requires 50 μL of blood. Collectively, the NanoBot's high sensitivity, accuracy, precision, and self-calibration characteristics signify its promising potential as a POCT platform for heart failure diagnosis in home use.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.016
Threshold uncertainty score0.635

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.008
GPT teacher head0.223
Teacher spread0.215 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueNanoscaleSame topicElectrochemical sensors and biosensorsFrench-language works237,207