MétaCan
Menu
Back to cohort
Record W2979100411 · doi:10.1177/0161734619879043

Performance Characteristics of Photoacoustic Imaging Probes with Varying Frequencies and Light-delivery Schemes

2019· article· en· W2979100411 on OpenAlexaff
Laurie J. Rich, Sarah Chamberlain, Daniela R. Falcone, Robert A. Bruce, Andrew Heinmiller, Jun Xia, Mukund Seshadri

Bibliographic record

VenueUltrasonic Imaging · 2019
Typearticle
Languageen
FieldEngineering
TopicPhotoacoustic and Ultrasonic Imaging
Canadian institutionsFujiFilm VisualSonics (Canada)
FundersNational Institute of Dental and Craniofacial ResearchNational Cancer InstituteNIH Office of the DirectorNational Institutes of HealthRoswell Park Alliance Foundation, Roswell Park Cancer Institute
KeywordsBiomedical engineeringUltrasoundPhotoacoustic imaging in biomedicineMaterials scienceDetectorOpticsMedical imagingPenetration depthAcousticsMedicineRadiologyPhysics

Abstract

fetched live from OpenAlex

Photoacoustic imaging (PAI) is an emerging biomedical imaging technique that utilizes a combination of light and ultrasound to detect photoabsorbers embedded within tissues. While the clinical utility of PAI has been widely explored for several applications, limitations in light penetration and detector sensitivity have restricted these studies to mostly superficial sites. Given the importance of PA signal generation and detection on light delivery and ultrasound detector frequency, there is an ongoing effort to optimize these parameters to enhance photoabsorber detection at increased depths. With this in mind, in this study we examined performance benchmarks of a commercially available PAI/ultrasound linear array system when using different imaging frequencies and light delivery schemes. A modified light fiber jacket providing focused light delivery (FLD) at the center of the probe was compared with the built-in fiber optics lining the length of the probe. Studies were performed in vitro to compare performance characteristics such as imaging resolution, maximum imaging depth, and sensitivity to varying hematocrit concentration for each frequency and light delivery method. Monte Carlo simulations of each light delivery method revealed increased light penetration with FLD. In tissue-mimicking phantoms, vascular channels used to simulate blood vessels could be visualized at a depth of 2.4 cm when lowering imaging frequency and utilizing FLD. Imaging at lower frequencies with FLD also enabled enhanced detection of varying hematocrit concentration levels at increased depths, although lateral imaging resolution was reduced. Finally, a proof of concept in vivo probe comparison study in a mouse tumor model provided supportive evidence of our in vitro results. Collectively, our findings show that adjusting imaging frequency and applying FLD can be a straightforward approach for improving PAI performance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.754
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.164
Teacher spread0.161 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueUltrasonic ImagingSame topicPhotoacoustic and Ultrasonic ImagingFrench-language works237,207