MétaCan
Menu
Back to cohort
Record W2979888716 · doi:10.1002/mp.13858

On the capabilities of conventional x‐ray tubes to deliver ultra‐high (FLASH) dose rates

2019· article· en· W2979888716 on OpenAlexafffund
Magdalena Bazalova‐Carter, Nolan Esplen

Bibliographic record

VenueMedical Physics · 2019
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsUniversity of Victoria
FundersBritish Columbia Knowledge Development FundNatural Sciences and Engineering Research Council of CanadaCanada Foundation for Innovation
KeywordsFlash (photography)DosimetryMaterials scienceMedical physicsMedical imagingDose rateNuclear medicineOpticsPhysicsNuclear engineeringMedicineRadiologyEngineering

Abstract

fetched live from OpenAlex

PURPOSE: By means of Monte Carlo (MC) simulations and indirect measurements, we have evaluated the maximum dose rates achievable with conventional x-ray tubes and related them to FLASH therapy dose rates of >40 Gy/s. METHODS: Monte Carlo models of two 160 kV x-ray tubes, the 3-kW MXR-160/22 and the 6-kW MXR-165, were built in the EGSnrc/BEAMnrc code. The dose rate in a water phantom placed against the x-ray tube surface, located at 3.7 and 3.5 cm from the focal spot for the MXR-160/22 and MXR-165 x-ray tube, respectively, was calculated with DOSXYZnrc. Dose delivered with the 120-kV beam in a plastic water phantom for the MXR-160/22 was measured and calculated. Gafchromic EBT3 films were placed at 15 and 18 mm depths in the plastic water phantom that was irradiated with a low tube current of 0.2 mA for 30 s. RESULTS: The maximum 160-kV phantom surface dose rate was determined to be FLASH capable, calculated as (114.3 ± 0.6) Gy/s and (160.0 ± 0.8) Gy/s for the MXR-160/22 and MXR-165 x-ray tubes, respectively. The dose rate in a 1-cm diameter region was found to be (110.6 ± 2.8) Gy/s and (151.9 ± 2.6) Gy/s and remained FLASH capable to depths of 1.4 and 2.0 mm for the MXR-160/22 and MXR-165 x-ray tube, respectively. The 120-kV dose profiles measured with EBT3 films agreed with MC simulations to within 3.6% for regions outside of heel effect and at both measurement depths; this presented a good validation data set for the simulations of phantom surface dose rate using the 160-kV beam. CONCLUSIONS: We have indirectly determined that, with a careful experimental design, conventional x-ray tubes can be made suitable for use in FLASH radiotherapy and dosimetry experiments.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Theoretical or conceptual · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.562
Threshold uncertainty score0.997

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0040.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.007
GPT teacher head0.262
Teacher spread0.255 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designTheoretical or conceptual
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations68
Published2019
Admission routes2
Has abstractyes

Explore more

Same venueMedical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207