MétaCan
Menu
← Back to cohort

Pseudoallergy Induced by Factor VIII Injection in Three Subjects with Hemophilia A

2011· article· en· W2979919762 on OpenAlexaff
Caroline Pfeiffer, Géraldine Lavigne-Lissalde, Georges‐Étienne Rivard

Bibliographic record

VenueBlood · 2011
Typearticle
Languageen
FieldMedicine
TopicHemophilia Treatment and Research
Canadian institutionsCentre Hospitalier Universitaire Sainte-Justine
Fundersnot available
KeywordsVon Willebrand factorMedicineImmunologyInternal medicinePlatelet

Abstract

fetched live from OpenAlex

Abstract Abstract 4353 BACKGROUND Hypersensitivity reactions to factor VIII (FVIII) concentrates are rare but well known complications of hemophilia treatment with FVIII concentrates. Occasional reports have suggested IgE mediation. Many cases have presented circumstantial evidence for the implication of FVIII but have failed to clearly identify FVIII-targeting antibodies (Abs). The absence of evidence for IgE contribution to those reactions, but the presence of FVIII specific IgM and/or IgG1 and/or IgG3, could support the hypothesis of complement mediation. These reactions have been called “complement activation-related pseudoallergy” (CARPA). As we did not study complement we call these reactions CARPA-like. We report 3 cases of CARPA-like reactions to FVIII which we believe could contribute to alert clinicians to this potential serious side effect of FVIII replacement therapy and could shed some light on its pathophysiology. PATIENTS / METHODS Subject A, 5 y. old Caucasian previously untreated patient (PUP) with mild hemophilia A (FVIII 0.12 IU/mL, 6955C>T exon 26 P2300S, H1 haplotype, no inhibitor with Nijmegen < 0.4 unit), developed a CARPA-like reaction with his sixth injection of a von Willebrand factor-containing FVIII concentrate (Wilate®, Octapharma) for traumatic knee hemarthrosis. He never needed further FVIII replacement. Subject B, 5 y. old African PUP with severe hemophilia A (FVIII < 0.01 IU/mL, intron 22 inversion, H1 haplotype, no inhibitor with Nijmegen < 0.4 unit) developed a CARPA-like reaction with his sixth injection of Wilate®. He was switched to a B-domain deleted recombinant FVIII concentrate (Xyntha™, Pfizer) and has yet to relapse with CARPA-like reaction after more than 100 exposure days. Subject C, 15 y. old Caucasian PUP with severe hemophilia A (FVIII < 0.01 IU/mL, intron 22 inversion, H1 haplotype, inhibitor with Nijmegen 10 units) developed a CARPA-like reaction with his second dose of a full length recombinant FVIII concentrate (Kogenate®,Bayer) while on ITI induction program. Blood samples were obtained from each patient shortly before and after their CARPA-like reaction. ELISA assays (AM. Vincent, Haemophila 2009) were used to test the presence of IgG, IgM, IgE Abs reacting with different types of FVIII (Baxter’s Advate, Wilate®, Kogenate®, Xyntha™) in patients’ plasma. The x-MAP technology was used to confirm the presence of IgG and IgM Abs, and to better define their isotypic profile. For that purpose, Abs specific for the heavy chain (HC; MAb 8860) or light chain (LC; MAb ESH8) of the FVIII were first immobilized on magnetic fluorescent beads, and then incubated with EDTA-dissociated FVIII. After incubation with patients’ plasma samples, binding of IgG subclasses (IgG1 to IgG4) and IgM were revealed by specific anti-human phycoerythrin-labeled Abs. RESULTS For patients A and B (with negative Bethesda titre), we identified an immune response characterized by the presence of IgM, as well as IgG (patient A IgG1; patient B IgG1, IgG3), simultaneously directed against the HC and the LC. ELISA assays on these 2 patients showed the presence of IgM and IgG, as well as the absence of IgE compatible with a CARPA-like reaction. Similar results with the 4 different FVIII concentrates are in favour of an immune response specific to FVIII rather than an immune response to anything else than FVIII. To further support this contention, ELISA assays were all negative for patient A’s mother and for his PUP hemophilic brother, as well as for subject B’s mother and for six normal control plasma tested on the same ELISA plate. Patient C (with positive Bethesda titre) presented anti-FVIII IgG (IgG1 to IgG4) and IgM Abs also targeting the HC and the LC simultaneously. These 3 patients developed a CARPA-like reaction associated with injection of FVIII concentrates. Subjects A and C were not rechallenged with FVIII after their reaction and progressively lost their anti-FVIII Abs. Subject B was rechallanged over 100 times with the B-domain deleted Xyntha™ without reaction and with progressive lost of his anti-FVIII Abs, suggesting that his reaction might have been mediated by Abs reacting to the B-domain of FVIII. CONCLUSION CARPA-like reactions to FVIII concentrates can be associated with anti-FVIII Abs. ELISA and x-MAP are useful technologies to investigate this complication of hemophilia treatment and could help select an optimal choice of FVIII concentrate for further replacement therapy. Disclosures: No relevant conflicts of interest to declare.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Case report · Consensus signal: Case report
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0030.001
Scholarly communication0.0010.001
Open science0.0000.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.044
GPT teacher head0.272
Teacher spread0.228 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designCase report
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueBlood→Same topicHemophilia Treatment and Research→French-language works237,207→