MétaCan
Menu
Back to cohort
Record W2980016651 · doi:10.1109/oses.2019.8867323

Transient Thermodynamic Assessment of the World's First Grid Connected UWCAES Facility by Exergy Analysis

2019· article· en· W2980016651 on OpenAlexaffabout
Mehdi Ebrahimi, Rupp Carriveau, David S.‐K. Ting, Andrew McGillis, Davin Young

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldEngineering
TopicThermodynamic and Exergetic Analyses of Power and Cooling Systems
Canadian institutionsHydro One (Canada)University of Windsor
Fundersnot available
KeywordsExergyExergy efficiencyGas compressorHeat exchangerEnvironmental scienceProcess engineeringTransient (computer programming)EngineeringMechanical engineeringComputer science

Abstract

fetched live from OpenAlex

Experience with Toronto's Underwater Compressed Air Energy Storage (UWCAES) facility has shown the technology to be more versatile than originally anticipated. Beyond typical steady-state operations, potentially valuable ancillary grid service roles can be assumed in the transient phase of its operation. This study examines the challenge to operate efficiently during UWCAES ramping events. A conventional and advanced exergy analysis is here conducted for the world's first grid connected UWCAES facility located in Toronto, Canada. A conventional exergy analysis showed that under real working conditions, the exergy efficiency of the plant is low during start-up. The exergy destruction rate, under unavoidable conditions, 2 minutes after the start of the transient phase is 42%, and this decreases asymptotically to 25%. An advanced analysis of exergy efficiency through a complete charge/discharge cycle suggested that the first improvement priority be given to the Heat Exchangers group. This should then be followed by the Ancillary, Compressor, Turbine, Motors and Generator and Pipelines groups. In terms of the rate of exergy destruction the analysis indicated that improvement priority for the Compressor group was higher than that for Heat Exchangers followed by Ancillary, Motors and Generator, Turbine and Pipelines groups. The advanced exergy analysis also revealed that 67% of the exergy destruction was endogenous and avoidable, highlighting the significant potential for performance improvement. Moreover, it was shown that with improvement in the system's component efficiencies, the plant exergy efficiency could be exogenously improved. This effect could further reduce the total exergy destruction to 76%, where only 9% is due to component-component interaction.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: Simulation or modeling
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.124
Threshold uncertainty score0.246

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.203
Teacher spread0.199 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations5
Published2019
Admission routes2
Has abstractyes

Explore more

Same topicThermodynamic and Exergetic Analyses of Power and Cooling SystemsFrench-language works237,207