Abstract

fetched live from OpenAlex

ABSTRACT Introduction Limb preservation procedures have become a much more common alternative to amputation after critical limb trauma, but high levels of disability result after both lower-limb amputation and lower-limb preservation. The Intrepid Dynamic Exoskeletal Orthosis (IDEO) is a custom passive-dynamic ankle-foot orthosis developed for use in military service members with critical lower-limb injuries. A proposed mechanism for pain reduction seen with the IDEO is decreased loading or pressure experienced during weight bearing. However, until this study, no actual plantar pressure data had confirmed this unloading during walking gait, and this proposed mechanism has not been examined. The aim of this study was to evaluate the effect of an IDEO on peak plantar pressure in the total foot as well as in each of the eight areas of the foot in a sample with foot and/or ankle injury. Methods For this within-subjects study, 74 potential participants who had been prescribed a unilateral IDEO were identified from a retrospective review of a clinical registry of patients. Patients were then excluded if they had bilateral lower-limb injury, spine or pelvis injury, or central neurological disorder, yielding 42 subjects (40 males). Patients were aged 29.7 ± 8.1 years. For each patient, data collection was performed before initiating training in use of the IDEO. Pressure-sensitive insoles were used to collect plantar pressure data in both shod and IDEO conditions at self-selected walking speeds. These trials were performed in a flat, linear hallway without turns or obstacles. The foot was divided into eight regions for analysis: medial and lateral sections of the hindfoot, midfoot, and forefoot, and greater and lesser toes. Results Peak pressures were significantly decreased in the affected foot with use of the IDEO with up to 64% decreases seen at the forefoot and toes. Increases in peak pressure of up to 24% were seen in some regions of the unaffected foot as well as the total foot. Discussion These findings help provide insight into the mechanism behind the improvement in function and decrease in pain that has been seen with use of the IDEO. The slight increases in plantar pressure seen in the unaffected foot with use of the IDEO may be due to higher gait velocity in the IDEO condition than in the shod condition (1.26 ± 0.14 m/s IDEO vs. 1.19 ± 0.17 m/s shod). Gait velocity was collected using instrumented gait analysis performed immediately before plantar pressure data collection. Alternately, overloading of the sound limb may be occurring due to unfamiliarity with the IDEO. Conclusions Despite a growing body of evidence for functional improvements with use of the IDEO, this is the first study to confirm that this brace can decrease peak plantar pressure, particularly in the forefoot and toes of the affected foot, during walking. This outcome provides insight to clinicians seeking a device to improve painful gait, particularly for conditions of the foot or ankle that produce pain in weight bearing. In addition, although the IDEO was designed to enable performance of high-level activities in a population with critical limb injury, this study provides support for using the IDEO for walking by those with a diverse collection of injuries.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.005

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.241
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2019
Admission routes1
Has abstractyes

Explore more

Same venueJPO Journal of Prosthetics and OrthoticsSame topicBone fractures and treatmentsFrench-language works237,207