MétaCan
Menu
Back to cohort
Record W2981067730 · doi:10.22055/jacm.2019.30017.1659

Effect of Coating Materials on the Fatigue Behavior of Hip Implants: A Three-dimensional Finite Element Analysis

2020· article· en· W2981067730 on OpenAlexaff
Mhd Ayham Darwich, Hasan Mhd Nazha, Monzer Daoud

Bibliographic record

VenueDOAJ (DOAJ: Directory of Open Access Journals) · 2020
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsÉcole de Technologie Supérieure
Fundersnot available
KeywordsPeekMaterials scienceFinite element methodCoatingComposite materialComposite numberImplantStress (linguistics)ProsthesisStructural engineeringCyclic stressSurgeryEngineeringMedicine

Abstract

fetched live from OpenAlex

This study aims to validate, using finite element analysis (FEA), the design concept by comparing the fatigue behavior of hip implant stems coated with composite (carbon/PEEK) and polymeric (PEEK) coating materials corresponding to different human activities: standing up, normal walking and climbing stairs under dynamic loadings to find out which of all these models have a better performance in the prosthesis-bone systems. A 3D finite element models of hip implants, femur, coating layers with polymeric (PEEK) and composite (carbon/PEEK) coating materials are created for FEA. The cyclic loads are applied on the prosthesis head. Fatigue life durations are calculated based on the Goodman mean-stress fatigue theory. The fatigue safety factor for the coated implant is increased more than 12.73% at least compared to the uncoated implant. The carbon/PEEK composite material with 0, +45, -45, and 90 degrees fiber orientation (configuration I) has the highest fatigue life and fatigue safety factor. The numerical result show that the carbon/PEEK composite material (configuration I) seems to be a good solution to increase the values of fatigue safety factor of coating layers due to highest fatigue life and fatigue safety factor. It distributes the applied load and transfers it to the bone, reducing stress-shielding effects and prolong the bone-prosthesis system life span.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.186
Threshold uncertainty score0.987

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0010.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0140.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.212
GPT teacher head0.509
Teacher spread0.297 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations32
Published2020
Admission routes1
Has abstractyes

Explore more

Same venueDOAJ (DOAJ: Directory of Open Access Journals)Same topicOrthopaedic implants and arthroplastyFrench-language works237,207